40m QIL Cryo_Lab CTN SUS_Lab CAML OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Sat Apr 6 02:07:40 2019, Anjali, Update, Frequency noise measurement, Frequency noise measurement of 1 micron source 
    Reply  Wed Apr 10 00:33:09 2019, Anjali, Update, Frequency noise measurement, Frequency noise measurement of 1 micron source Modulation_frequency_100Hz.jpgModulation_frequency_30Hz.jpgModified_setup.JPG
       Reply  Wed Apr 10 16:58:54 2019, rana, Update, IOO, fiber MZ for NPRO freq noise measurements 
          Reply  Wed Apr 10 22:59:22 2019, gautam, Update, IOO, Spooled fiber 
             Reply  Thu Apr 11 09:05:06 2019, Anjali, Update, IOO, Spooled fiber Frequecy_modulation_32_Hz.pdfFrequecy_modulation_140_Hz.pdfFrequecy_modulation_300_Hz.pdfWithout_modulation.pdfNew_fiber_spool.JPG
       Reply  Fri Apr 12 01:22:27 2019, Anjali, Update, Frequency noise measurement, Frequency noise measurement of 1 micron source 
          Reply  Mon Apr 15 22:39:10 2019, gautam, Update, Frequency noise measurement, Alternate setup with PSL pickoff 
             Reply  Wed Apr 17 00:43:38 2019, gautam, Update, Frequency noise measurement, MZ interferometer ---> DAQ 
                Reply  Thu Apr 25 03:32:25 2019, Anjali, Update, Frequency noise measurement, MZ interferometer ---> DAQ Time_domain_output.pdfFrequency_noise.pdfschematic_heterodyne_setup.pngNoise_budget_1_micron_in_Hz_per_rtHz.pdf
                   Reply  Thu Apr 25 10:25:19 2019, gautam, Update, Frequency noise measurement, Homodyne v Heterodyne 
                      Reply  Thu Apr 25 15:47:54 2019, Anjali, Update, Frequency noise measurement, Homodyne v Heterodyne Experimental_setup.JPG
Message ID: 14547     Entry time: Wed Apr 17 00:43:38 2019     In reply to: 14544     Reply to this: 14571
Author: gautam 
Type: Update 
Category: Frequency noise measurement 
Subject: MZ interferometer ---> DAQ 
  1. Delay fiber was replaced with 5m (~30 nsec delay)
    • The fringing of the MZ was way too large even with the free running NPRO (~3 fringes / sec)
    • Since the V/Hz is proportional to the delay, I borrowed a 5m patch cable from Andrew/ATF lab, wrapped it around a spool, and hooked it up to the setup
    • Much more satisfactory fringing rate (~1 wrap every 20 sec) was observed with no control to the NPRO
  2. MZ readout PDs hooked up to ALS channels
    • To facilitate further quantitative study, I hooked up the two PDs monitoring the two ports of the MZ to the channels normally used for ALS X.
    • ZHL3-A amps inputs were disconnected and were turned off. Then cables to their outputs were highjacked to pipe the DC PD signals to the 1Y3 rack
    • Unfortunately there isn't a DQ-ed fast version of this data (would require a model restart of c1lsc which can be tricky), but we can already infer the low freq fringing rate from overnight EPICS data and also use short segments of 16k data downloaded "live" for the frequency noise measurement.
    • Channels are C1:ALS-BEATX_FINE_I_IN1 and C1:ALS-BEATX_FINE_Q_IN1 for 16k data, and C1:ALS-BEATX_FINE_I_INMON and C1:ALS-BEATX_FINE_I_INMON for 16 Hz.

At some point I'd like to reclaim this setup for ALS, but meantime, Anjali can work on characterization/noise budgeting. Since we have some CDS signals, we can even think of temperature control of the NPRO using pythonPID to keep the fringe in the linear regime for an extended period of time.

ELOG V3.1.3-