40m
QIL
Cryo_Lab
CTN
SUS_Lab
TCS_Lab
OMC_Lab
CRIME_Lab
FEA
ENG_Labs
OptContFac
Mariner
WBEEShop
|
40m Log |
Not logged in |
 |
|
Wed Feb 20 23:55:51 2019, gautam, Update, ALS, ALS delay line electronics
|
Thu Mar 7 01:06:38 2019, gautam, Update, ALS, ALS delay line electronics
|
Tue Mar 12 22:51:25 2019, gautam, Update, ALS, ALS delay line electronics
|
Wed Mar 13 01:27:30 2019, gautam, Update, ALS, ALS delay line electronics 
|
Sun Mar 17 00:42:20 2019, gautam, Update, ALS, NF1611 cannot be shot-noise limited?
|
Thu Mar 28 19:40:02 2019, gautam, Update, ALS, BeatMouth with NF1611s assembled   
|
Fri Mar 29 21:00:06 2019, gautam, Update, ALS, BeatMouth with NF1611s installed 
|
Sun Mar 31 15:05:53 2019, gautam, Update, ALS, Fiber beam-splitters not PM
|
Wed Apr 3 09:04:01 2019, gautam, Update, ALS, Note about new fiber couplers
|
Wed Apr 3 12:32:33 2019, Koji, Update, ALS, Note about new fiber couplers
|
Fri Apr 5 00:33:58 2019, gautam, Update, ALS, Promising IR ALS noise 
|
Fri Apr 5 11:49:30 2019, gautam, Update, ALS, PSL + X green beat recovery
|
Mon Apr 8 00:04:08 2019, gautam, Update, ALS, IR ALS noise budget
|
Mon Apr 8 18:28:25 2019, gautam, Update, ALS, EX Green PDH checkout 
|
Mon Apr 8 23:52:09 2019, gautam, Update, ALS, EX Green PDH error monitor calibrated   
|
Tue Apr 9 00:16:22 2019, rana, Update, ALS, EX Green PDH error monitor calibrated
|
Tue Apr 9 00:18:19 2019, gautam, Update, ALS, EX Green PDH error monitor calibrated
|
Tue Apr 9 18:44:00 2019, gautam, Update, ALS, EX Green PDH discriminant measurement 
|
Tue Apr 9 19:07:12 2019, gautam, Update, ALS, IR ALS noise budget 
|
Thu Apr 11 01:10:05 2019, gautam, Update, ALS, Large 2kHz peak (and harmonics) in ALS X
|
Wed Apr 17 00:50:17 2019, gautam, Update, ALS, Large 2kHz peak (and harmonics) in ALS X no more
|
Wed Apr 17 11:01:49 2019, gautam, Update, ALS, Large 2kHz peak (and harmonics) in ALS X no more
|
Wed May 29 18:13:25 2019, gautam, Update, ALS, Fiber beam-splitters are now PM
|
Fri May 31 15:55:16 2019, gautam, Update, ALS, PSL + X beat restored
|
|
Message ID: 14528
Entry time: Tue Apr 9 19:07:12 2019
In reply to: 14521
Reply to this: 14533
|
Author: |
gautam |
Type: |
Update |
Category: |
ALS |
Subject: |
IR ALS noise budget |
|
|
Updated the noise budget to include the unsuppressed frequency noise from the EX laser. It does not explain the noise between 10-100 Hz, although the 1-3 Hz noise is close.
Actually, I think the curve that should go on the budget is when the X arm length is locked to the PSL frequency, whereas this is when the X arm is just locally damped. I will update it later tonight.
Update 1010pm: I've uploaded the relevant plot as Attachment #2. Predictably, the unsuppressed frequency noise of the EX laser is now higher, because the MC length is a noisier frequency reference than the arm cavity. But still it is a factor of 10 below the measured ALS noise.
Quote: |
Next noises to budget:
- In-loop X arm length noise
- In-lop EX laser frequency noise
|
|
|
|
|
|