Message ID: 14470     Entry time: Mon Feb 25 20:20:07 2019
Author: Koji 
Type: Update 
Category: SUS 
Subject: DIN 41612 (96pin) shrouds installed to vertex SUS coil drivers 

The forthcoming Acromag c1susaux is supposed to use the backplane connectors of the sus euro card modules.

However, the backplane connectors of the vertex sus coil drivers were already used by the fast switches (dewhitening) of c1sus.

Our plan is to connect the Acromag cables to the upper connectors, while the switch channels are wired to the lower connector by soldering jumper wires between the upper and lower connectors on board.

To make the lower 96pin DIN connector available for this, we needed DIN 41612 (96pin) shroud. Tyco Electronics 535074-2 is the correct component for this purpose. The shrouds have been installed to the backplane pins of the coil driver circuit D010001. The shroud has the 180deg rotation dof. The direction of the shroud was matched with the ones on the upper connectors.

Attachment 1: P_20190222_175058.jpg  712 kB  | Hide | Hide all
P_20190222_175058.jpg