Entry  Fri Feb 15 20:07:02 2019, Jon, Update, VAC, Updated vacuum punch list 
    Reply  Fri Feb 15 21:15:42 2019, gautam, Update, VAC, dd backup of c1vac made 
Message ID: 14462     Entry time: Fri Feb 15 21:15:42 2019     In reply to: 14461
Author: gautam 
Type: Update 
Category: VAC 
Subject: dd backup of c1vac made 
  1. Connected one of the solid-state drives to c1vac. It was /dev/sdb.
  2. Formatted the drive using sudo mkfs -t ext4 /dev/sdb
  3.  Mounted it as /mnt/backup using sudo mount /dev/sdb /mnt/backup
  4. Started a tmux session for the dd, called DDbackup
  5. Started the dd backup using  sudo dd if=/dev/sda of=/dev/sdb bs=64K conv=noerror,sync
  6. Backup completed in 719 seconds: need to test if it works...
controls@c1vac:~$ sudo dd if=/dev/sda of=/dev/sdb bs=64K conv=noerror,sync
[sudo] password for controls: 
^C283422+0 records in
283422+0 records out
18574344192 bytes (19 GB) copied, 719.699 s, 25.8 MB/s
Quote:
 
  • Generate a bootable backup hard drive for c1vac, which could be swapped in on a short time scale after a failure.
ELOG V3.1.3-