Message ID: 14447     Entry time: Mon Feb 11 16:38:34 2019     In reply to: 14446
Author: gautam 
Type: Update 
Category: LSC 
Subject: ETMY OL calibration updated 

Since we changed the HeNe, I updated the calibration factors, and accepted the changes in the SDF.

DOF OLD [urad/ct] NEW [urad/ct]
PITCH 140 176
YAW 143

193

Attachment 1: OL_calib_ETMY_PERROR.pdf  83 kB  | Show | Hide all | Show all
Attachment 2: OL_calib_ETMY_YERROR.pdf  84 kB  | Hide | Hide all | Show all