40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Tue Aug 14 23:14:24 2018, aaron, Update, OMC, OMC scanning/aligning script 
    Reply  Tue Nov 20 20:33:11 2018, aaron, Update, OMC, OMC scanning/aligning script pathwaysketch.pdfIMG_0094.JPGIMG_0097.JPG
       Reply  Mon Nov 26 15:43:16 2018, aaron, Update, OMC, OMC scanning/aligning script c1omc.png
          Reply  Thu Dec 6 11:16:28 2018, aaron, Update, OMC, OMC channels 
             Reply  Mon Dec 10 12:29:05 2018, aaron, Update, OMC, OMC channels 52DE723A-02A4-4C62-879B-7B0070AE8A00.jpeg545E5512-D003-408B-9F00-55F985966A16.jpegDFF34976-CC49-4E4F-BFD1-A197E2072A32.jpeg
                Reply  Mon Dec 10 19:47:06 2018, aaron, Update, OMC, OMC channels 
                   Reply  Tue Dec 11 13:42:44 2018, Koji, Update, OMC, OMC channels 
                   Reply  Tue Dec 11 13:48:04 2018, aaron, Update, OMC, OMC channels 
                      Reply  Thu Dec 13 22:24:21 2018, aaron, Update, OMC, OMC channels 
          Reply  Mon Dec 10 12:11:28 2018, aaron, Update, OMC, Aligning the OMC B9DCF55F-1355-410C-8A29-EE45D43A56A4.jpeg
             Reply  Tue Dec 11 14:24:18 2018, aaron, Update, OMC, Aligning the OMC 
                Reply  Tue Dec 11 22:50:07 2018, aaron, Update, OMC, Aligning the OMC 6x
                   Reply  Thu Dec 13 22:36:42 2018, aaron, Update, OMC, Aligning the OMC 
                      Reply  Fri Dec 14 13:02:24 2018, aaron, Update, OMC, Aligning the OMC 
                      Reply  Fri Dec 14 13:06:12 2018, aaron, Update, OMC, Aligning the OMC 
                         Reply  Mon Dec 17 20:45:40 2018, aaron, Update, OMC, Aligning the OMC IMG_5922.JPGIMG_5921.JPG
                            Reply  Tue Dec 18 18:13:32 2018, aaron, Update, OMC, OMC L HV Piezo driver tests (again) IMG_4576_copy.jpg
                               Reply  Wed Dec 19 00:12:46 2018, gautam, Update, OMC, 40m OMC DCC node 
Message ID: 14342     Entry time: Tue Dec 11 13:48:04 2018     In reply to: 14340     Reply to this: 14354
Author: aaron 
Type: Update 
Category: OMC 
Subject: OMC channels 

Koji gave me some tips on testing this board that I wanted to write down, notes probably a bit intermingled with my thoughts. Thanks Koji, also for the DCC and equipment logging!

  • Test the power and AI boards separately with an external supply, ramping the voltage up slowly for each.
  • If it seems the AI board is actually drawing too much current, may need to check its TPs for where a problem might be
    • If it's really extensive may use an IR camera to see what elements are getting too hot
    • Testing in segments will prevent breaking more components
  • Check the regulator that I've replaced
  • The 1 Ohm resistors may have been acting as extra 1A fuses. i need to make sure the resistors I've used to replace them are rated for >1W, if this is the case.
  • Can check the resistance between +-12V and Gnd inputs on the AI board, if there is a short drawing too much current it may show up there.
  • The 7812 may be an appropriate regulator, but the input voltage may need to be somewhat higher than with the low drop regulator that was used before.
  • I want to double check the diagram on the DCC