40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Tue Aug 14 23:14:24 2018, aaron, Update, OMC, OMC scanning/aligning script 
    Reply  Tue Nov 20 20:33:11 2018, aaron, Update, OMC, OMC scanning/aligning script pathwaysketch.pdfIMG_0094.JPGIMG_0097.JPG
       Reply  Mon Nov 26 15:43:16 2018, aaron, Update, OMC, OMC scanning/aligning script c1omc.png
          Reply  Thu Dec 6 11:16:28 2018, aaron, Update, OMC, OMC channels 
             Reply  Mon Dec 10 12:29:05 2018, aaron, Update, OMC, OMC channels 52DE723A-02A4-4C62-879B-7B0070AE8A00.jpeg545E5512-D003-408B-9F00-55F985966A16.jpegDFF34976-CC49-4E4F-BFD1-A197E2072A32.jpeg
                Reply  Mon Dec 10 19:47:06 2018, aaron, Update, OMC, OMC channels 
                   Reply  Tue Dec 11 13:42:44 2018, Koji, Update, OMC, OMC channels 
                   Reply  Tue Dec 11 13:48:04 2018, aaron, Update, OMC, OMC channels 
                      Reply  Thu Dec 13 22:24:21 2018, aaron, Update, OMC, OMC channels 
          Reply  Mon Dec 10 12:11:28 2018, aaron, Update, OMC, Aligning the OMC B9DCF55F-1355-410C-8A29-EE45D43A56A4.jpeg
             Reply  Tue Dec 11 14:24:18 2018, aaron, Update, OMC, Aligning the OMC 
                Reply  Tue Dec 11 22:50:07 2018, aaron, Update, OMC, Aligning the OMC 6x
                   Reply  Thu Dec 13 22:36:42 2018, aaron, Update, OMC, Aligning the OMC 
                      Reply  Fri Dec 14 13:02:24 2018, aaron, Update, OMC, Aligning the OMC 
                      Reply  Fri Dec 14 13:06:12 2018, aaron, Update, OMC, Aligning the OMC 
                         Reply  Mon Dec 17 20:45:40 2018, aaron, Update, OMC, Aligning the OMC IMG_5922.JPGIMG_5921.JPG
                            Reply  Tue Dec 18 18:13:32 2018, aaron, Update, OMC, OMC L HV Piezo driver tests (again) IMG_4576_copy.jpg
                               Reply  Wed Dec 19 00:12:46 2018, gautam, Update, OMC, 40m OMC DCC node 
Message ID: 14338     Entry time: Mon Dec 10 12:29:05 2018     In reply to: 14332     Reply to this: 14340
Author: aaron 
Type: Update 
Category: OMC 
Subject: OMC channels 

I kept having trouble keeping the power LEDs on the dewhitening board 'on'. I did the following:

1. I noticed that the dewhitening board was drawing a lot of current (>500mA), so I initially thought that the indicators were just turning on until I blew the fuse. I couldn't find the electronics diagrams for this board, so I was using analagous boards' diagrams and wasn't sure how much current to expect to draw. I swapped out for 1A fuses (only for the electronics I was adding to the system).

2. Now the +24V indicator on the dewhitening board wasn't turning on, and the -24V supply was alternatively drawing ~500mA and 0mA in a ~1Hz square wave. Thinking I could be dropping voltage along the path to the board, I swapped out the cables leading to the whitening/dewhitening boards with 16AWG (was 18AWG). This didn't seem to help.

3. Since the whitening board seemed to be consistently powered on, I removed the dewhitening board to see if there was a problem with it. Indeed, I'd burned out the +24V supply electronics--two resisters were broken entirely, and the breadboard near the voltage regulator had been visibly heated.

  1. I identified that the resistors were 1Ohm, and replaced them (though I couldn't find 1Ohm surface mount resistors). I also replaced the voltage regulator in case it was broken. I couldn't find the exact model, so I replaced the LM2940CT-12 with an LM7812, which I think is the newer 12V regulator.
  2. Though this replacement seemed to work when the power board was disconnected from the dewhitening board, connecting to the dewhitening board again resulted in a lot of current draw.
  3. I depowered the board and decided to take a different approach (see)

I noticed that the +/-15V currents are slightly higher than the labels, but didn't notice whether they were already different before I began this work.

I also noticed one pair of wires in the area of 1X1 I was working that wasn't attached to power (or anything). I didn't know what it was for, so I've attached a picture.

Attachment 1: 52DE723A-02A4-4C62-879B-7B0070AE8A00.jpeg  3.266 MB  | Show | Hide all | Show all
Attachment 2: 545E5512-D003-408B-9F00-55F985966A16.jpeg  2.776 MB  | Show | Hide all | Show all
Attachment 3: DFF34976-CC49-4E4F-BFD1-A197E2072A32.jpeg  2.726 MB  | Hide | Hide all | Show all
DFF34976-CC49-4E4F-BFD1-A197E2072A32.jpeg
ELOG V3.1.3-