Not logged in |
 |
|
Tue Jul 17 12:55:45 2018, Koji, Summary, General, Started pumping 6x
|
Tue Jul 17 18:16:38 2018, Steve, Summary, VAC, pumpdown 81 at 6 hrs 6x
|
Tue Jul 17 22:25:41 2018, Koji, Summary, VAC, pumpdown 81 at 6 hrs
|
Wed Jul 18 12:49:08 2018, Steve, Summary, VAC, pumpdown 81 at 6 +4.5hrs  
|
Wed Jul 18 17:36:50 2018, Steve, Summary, VAC, pumpdown 81 at 6 +9 hrs completed 
|
Thu Jul 19 01:56:25 2018, gautam, Summary, VAC, AUX pump shutdown
|
Thu Jul 19 11:01:03 2018, Steve, Summary, VAC, pd81 @ 2e-5 Torr
|
Thu Jul 19 13:35:30 2018, Steve, Summary, VAC, annuloses pumped
|
Mon Jul 23 09:58:52 2018, Steve, Summary, VAC, RGA scan at day 6
|
Mon Aug 6 09:34:02 2018, Steve, Update, VAC, RGA scan at day 20
|
Thu Aug 16 07:50:28 2018, Steve, Update, VAC, pumpdown 81 at day 30
|
Thu Aug 16 14:48:14 2018, Steve, Update, VAC, why do we need a root pump? 6x
|
Fri Nov 16 10:26:12 2018, Steve, Update, VAC, single viton O-rings
|
Fri Aug 24 10:51:23 2018, Steve, Update, VAC, pumpdown 81 at day 38
|
Thu Oct 4 08:25:50 2018, Steve, Update, VAC, rga scan pd81 at day 78
|
Fri Oct 12 08:27:05 2018, Steve, Update, VAC, drypump
|
Fri Oct 12 17:37:03 2018, Steve, Update, VAC, pressure gauge choices
|
Mon Oct 15 13:59:42 2018, Steve, Update, VAC, drypump replaced
|
Tue Nov 13 16:15:01 2018, Steve, Update, VAC, rga scan pd81 at day 119 
|
|
Message ID: 14244
Entry time: Fri Oct 12 08:27:05 2018
In reply to: 14229
Reply to this: 14247
14256
|
Author: |
Steve |
Type: |
Update |
Category: |
VAC |
Subject: |
drypump |
|
|
Gautam and Steve,
Our TP3 drypump seal is at 360 mT [0.25A load on small turbo] after one year. We tried to swap in old spare drypump with new tip seal. It was blowing it's fuse, so we could not do it.
Noisy aux drypump turned on and opened to TP3 foreline [ two drypumps are in the foreline now ] The pressure is 48 mT and 0.17A load on small turbo. |
|
|