40m
QIL
Cryo_Lab
CTN
SUS_Lab
TCS_Lab
OMC_Lab
CRIME_Lab
FEA
ENG_Labs
OptContFac
Mariner
WBEEShop
|
40m Log |
Not logged in |
 |
|
Sun Aug 5 13:28:43 2018, gautam, Update, CDS, c1lsc flaky
|
Mon Aug 6 00:26:21 2018, gautam, Update, CDS, More CDS woes
|
Mon Aug 6 14:38:38 2018, gautam, Update, CDS, More CDS woes 
|
Mon Aug 6 19:49:09 2018, gautam, Update, CDS, More CDS woes
|
Tue Aug 7 11:30:46 2018, gautam, Update, CDS, More CDS woes
|
Tue Aug 7 22:28:23 2018, gautam, Update, CDS, More CDS woes
|
Wed Aug 8 23:03:42 2018, gautam, Update, CDS, c1lsc model started
|
Thu Aug 9 12:31:13 2018, gautam, Update, CDS, CDS status update
|
Wed Aug 15 21:27:47 2018, gautam, Update, CDS, CDS status update
|
Tue Sep 4 10:14:11 2018, gautam, Update, CDS, CDS status update
|
Wed Sep 5 10:59:23 2018, wgautam, Update, CDS, CDS status update
|
Thu Sep 6 14:21:26 2018, gautam, Update, CDS, ADC replacement in c1lsc expansion chassis
|
Fri Sep 7 12:35:14 2018, gautam, Update, CDS, ADC replacement in c1lsc expansion chassis
|
Mon Sep 10 12:44:48 2018, Jon, Update, CDS, ADC replacement in c1lsc expansion chassis
|
Thu Sep 20 11:29:04 2018, gautam, Update, CDS, New PCIe fiber housed 
|
Thu Sep 20 16:19:04 2018, gautam, Update, CDS, New PCIe fiber install postponed to tomorrow
|
Fri Sep 21 16:46:38 2018, gautam, Update, CDS, New PCIe fiber installed and routed 
|
|
Message ID: 14202
Entry time: Thu Sep 20 11:29:04 2018
In reply to: 14194
Reply to this: 14203
|
Author: |
gautam |
Type: |
Update |
Category: |
CDS |
Subject: |
New PCIe fiber housed |
|
|
[steve, yuki, gautam]
The plastic tubing/housing for the fiber arrived a couple of days ago. We routed ~40m of fiber through roughly that length of the tubing this morning, using some custom implements Steve sourced. To make sure we didn't damage the fiber during this process, I'm now testing the vertex models with the plastic tubing just routed casually (= illegally) along the floor from 1X4 to 1Y3 (NOTE THAT THE WIKI PAGE DIAGRAM IS OUT OF DATE AND NEEDS TO BE UPDATED), and have plugged in the new fiber to the expansion chassis and the c1lsc front end machine. But I'm seeing a DC error (0x4000), which is indicative of some sort of timing error (Attachment #1) **. Needs more investigation...
Pictures + more procedural details + proper routing of the protected fiber along cable trays after lunch. If this doesn't help the stability problem, we are out of ideas again, so fingers crossed...
** In the past, I have been able to fix the 0x4000 error by manually rebooting fb (simply restarting the daqd processes on fb using sudo systemctl restart daqd_* doesn't seem to fix the problem). Sure enough, seems to have done the job this time as well (Attachment #2). So my initial impression is that the new fiber is functioning alright .
Quote: |
The PCIe fiber replacement is a more involved project (Steve is acquiring some protective tubing to route it from the FE in 1X6 to the expansion chassis in 1Y3)
|
|
|
|
|
|