40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Sun Aug 5 13:28:43 2018, gautam, Update, CDS, c1lsc flaky 
    Reply  Mon Aug 6 00:26:21 2018, gautam, Update, CDS, More CDS woes CDSoverview.png
       Reply  Mon Aug 6 14:38:38 2018, gautam, Update, CDS, More CDS woes CDScrash.pngMC1failures.png
          Reply  Mon Aug 6 19:49:09 2018, gautam, Update, CDS, More CDS woes IMG_7106.JPG
             Reply  Tue Aug 7 11:30:46 2018, gautam, Update, CDS, More CDS woes 
                Reply  Tue Aug 7 22:28:23 2018, gautam, Update, CDS, More CDS woes 
                   Reply  Wed Aug 8 23:03:42 2018, gautam, Update, CDS, c1lsc model started 
                      Reply  Thu Aug 9 12:31:13 2018, gautam, Update, CDS, CDS status update 
                         Reply  Wed Aug 15 21:27:47 2018, gautam, Update, CDS, CDS status update 
                            Reply  Tue Sep 4 10:14:11 2018, gautam, Update, CDS, CDS status update 
                               Reply  Wed Sep 5 10:59:23 2018, wgautam, Update, CDS, CDS status update 
                                  Reply  Thu Sep 6 14:21:26 2018, gautam, Update, CDS, ADC replacement in c1lsc expansion chassis CDSoverview.png
                                     Reply  Fri Sep 7 12:35:14 2018, gautam, Update, CDS, ADC replacement in c1lsc expansion chassis Screenshot_from_2018-09-07_12-34-52.png
                                        Reply  Mon Sep 10 12:44:48 2018, Jon, Update, CDS, ADC replacement in c1lsc expansion chassis 
                                     Reply  Thu Sep 20 11:29:04 2018, gautam, Update, CDS, New PCIe fiber housed PCIeFiberSwap.pngPCIeFiberSwap_FBrebooted.png
                                        Reply  Thu Sep 20 16:19:04 2018, gautam, Update, CDS, New PCIe fiber install postponed to tomorrow 
                                           Reply  Fri Sep 21 16:46:38 2018, gautam, Update, CDS, New PCIe fiber installed and routed PCIeFiber.pngIMG_5878.JPG
Message ID: 14139     Entry time: Mon Aug 6 14:38:38 2018     In reply to: 14136     Reply to this: 14140
Author: gautam 
Type: Update 
Category: CDS 
Subject: More CDS woes 

Stability was short-lived it seems. When I came in this morning, all models on c1lsc were dead already, and now c1sus is also dead (Attachment #1). Moreover, MC1 shadow sensors failed for a brief period again this afternoon (Attachment #2). I'm going to wait for some CDS experts to take a look at this since any fix I effect seems to be short-lived. For the MC1 shadow sensors, I wonder if the Trillium box (and associated Sorensen) failure somehow damaged the MC1 shadow sensor/coil driver electronics.

Quote:
 

Let's see how stable this configuration is. Onto some locking now...

Attachment 1: CDScrash.png  96 kB  Uploaded Mon Aug 6 15:40:02 2018  | Show | Show all
Attachment 2: MC1failures.png  30 kB  Uploaded Mon Aug 6 15:42:44 2018  | Show | Show all
ELOG V3.1.3-