Entry  Thu Mar 12 15:57:53 2009, Yoichi, Update, IOO, MC drift is terrible MC_Drift-1.pdfMC_Drift-2.pdf
    Reply  Thu Mar 12 19:11:27 2009, rana, Update, IOO, MC drift is terrible 
       Reply  Thu Mar 12 20:59:04 2009, Kakeru, Update, IOO, MC drift is terrible MCtrans090312.png
Message ID: 1397     Entry time: Thu Mar 12 19:11:27 2009     In reply to: 1394     Reply to this: 1398
Author: rana 
Type: Update 
Category: IOO 
Subject: MC drift is terrible 
Kakeru, Rana, Yoichi

We used the SUS DRIFT MON screen to set the MC biases such that the mirrors were returned to the old OSEM values.
To do this, we set the nominals and tolerances using the appropriate scripts in the mDV/extra/C1/ directory.

We then used the MC_ALIGN screen to set the angle bias sliders.

Then Kakeru and I went to the PSL table to the periscope magic and maximize the MC transmission. Kakeru seems to
have the careful Japanese alignment touch and I am hungry, so I am leaving him to optimize the power. After he
finishes he is going to align the beam to the WFS and turn the MC autolocker back on. The x-arm is locked on a
TEM00 mode so the MC alignment is maybe OK.