Mon Jun 11 23:22:53 2018, gautam, Update, CDS, EX wiring confusion
|
Wed Jun 13 23:23:44 2018, johannes, Update, CDS, EX wiring confusion 
|
Thu Jun 14 10:41:00 2018, gautam, Update, CDS, EX wiring confusion
|
Thu Jun 14 15:31:18 2018, johannes, Update, CDS, EX wiring confusion 
|
|
Message ID: 13958
Entry time: Wed Jun 13 23:23:44 2018
In reply to: 13947
Reply to this: 13961
|
Author: |
johannes |
Type: |
Update |
Category: |
CDS |
Subject: |
EX wiring confusion |
|
|
It's true.
I went through the wiring of the c1auxex crate today to disentangle the pin assignments. The full detail can be found in attachment #1, #2 has less detail but is more eye candy. The red flagged channels are now marked for removal at the next opportunity. This will free up DAQ channels as follows:
TYPE |
Total |
Available now |
Available after |
ADC |
24 |
2 |
14 |
DAC |
16 |
8 |
12 |
BIO sinking |
16 |
7 |
7 |
BIO sourcing |
8 |
8 |
8 |
This should be enough for temperature sensing, NPRO diagnostics, and even eventual remote PDH control with new servo boxes. |
|
|
|
|