40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Fri Jun 8 14:40:55 2018, c1lsc, Update, CDS, i am dead 31.png
    Reply  Fri Jun 8 20:15:08 2018, gautam, Update, CDS, Reboot script 31.png
       Reply  Mon Jun 11 18:49:06 2018, gautam, Update, CDS, c1lsc dead again 36.png
       Reply  Wed Dec 4 09:11:42 2019, Yehonathan, Update, CDS, Reboot script medmScreen11.ps
          Reply  Wed Dec 4 12:13:10 2019, gautam, Update, CDS, Reboot script 
Message ID: 13942     Entry time: Mon Jun 11 18:49:06 2018     In reply to: 13935
Author: gautam 
Type: Update 
Category: CDS 
Subject: c1lsc dead again 

Why is this happening so frequently now? Last few lines of error log:

[  575.099793] c1oaf: DAQ EPICS: Int = 199  Flt = 706 Filters = 9878 Total = 10783 Fast = 113
[  575.099793] c1oaf: DAQ EPICS: Number of Filter Module Xfers = 11 last = 98
[  575.099793] c1oaf: crc length epics = 43132
[  575.099793] c1oaf:  xfer sizes = 128 788 100988 100988 
[240629.686307] c1daf: ADC TIMEOUT 0 43039 31 43103
[240629.686307] c1cal: ADC TIMEOUT 0 43039 31 43103
[240629.686307] c1ass: ADC TIMEOUT 0 43039 31 43103
[240629.686307] c1oaf: ADC TIMEOUT 0 43039 31 43103
[240629.686307] c1lsc: ADC TIMEOUT 0 43039 31 43103
[240630.684493] c1x04: timeout 0 1000000 
[240631.684938] c1x04: timeout 1 1000000 
[240631.684938] c1x04: exiting from fe_code()

I fixed it by running the reboot script.

Attachment 1: 36.png  25 kB  Uploaded Mon Jun 11 19:51:48 2018  | Show | Show all