Tue May 8 11:41:16 2018, gautam, Update, General, IFO maintenance
|
Wed May 9 17:30:04 2018, gautam, Update, General, Input beam misaligned 
|
Wed May 9 19:51:07 2018, gautam, Update, General, Input beam misaligned 
|
Sun May 13 15:15:18 2018, gautam, Update, General, CDS crash
|
Sun May 13 17:31:51 2018, gautam, Update, General, CDS crash 
|
Sun May 13 20:48:38 2018, johannes, Update, General, CDS crash
|
Thu May 17 11:56:37 2018, gautam, Update, General, EPICS process died on c1ioo
|
Thu May 24 10:16:29 2018, gautam, Update, General, All models on c1lsc frontend crashed
|
Thu May 10 08:45:16 2018, Steve, Update, General, 4.5M eq. Cabazon, CA 
|
Thu May 10 11:38:19 2018, gautam, Update, General, ITMY UL
|
Wed Aug 22 08:44:09 2018, Steve, Update, General, earth quake
|
Fri Aug 24 08:04:37 2018, Steve, Update, General, small earth quake
|
Mon Aug 27 09:14:45 2018, Steve, Update, PEM, small earth quakes
|
Tue Nov 27 10:50:20 2018, Steve, Update, PEM, earth quake Mexico
|
Thu Nov 29 08:13:33 2018, Steve, Update, PEM, EQ 3.9m So CA  
|
Wed Aug 29 09:20:27 2018, Steve, Update, SUS, local 4.4M earth quake 
|
Wed Aug 29 11:46:27 2018, Jon, Update, SUS, local 4.4M earth quake
|
Thu Sep 20 08:17:14 2018, Steve, Update, SUS, local 3.4M earth quake
|
|
Message ID: 13827
Entry time: Wed May 9 17:30:04 2018
In reply to: 13826
Reply to this: 13828
|
Author: |
gautam |
Type: |
Update |
Category: |
General |
Subject: |
Input beam misaligned |
|
|
There is no beam going into the IFO at the moment. There was definitely a spot on the AS camera after I restored the suspensions yesterday, as you can see from the ASDC level in Attachment #1. But at around 2pm Pacific yesterday, the ASDC level has gone to 0. I suspect the TTs. There is no beam on the REFL camera either when PRM is aligned, and PRM's DC alignment is good as judged by Oplev.
Normally, I am able to recover the beam by scanning the TTs around with some low frequency sine waves, but not today. We don't have any readback (Oplev/OSEM) of the TT alignment, and the DC bias values havent jumped abnormally around the time this happened, judging by the OUT16 monitor points (see Attachment #2). The IMC was also locked at the time when this abrupt drop in ASDC level happened. Unfortunately, we don't have a camera on the Faraday so I don't know where the misalignment is happening, but the beam is certainly not making it to the BS. All the SOS optics (e.g. BS, ITMX and ITMY) are well aligned as judged by Oplev.
Being debugged now... |
|
|
|