40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Mon Mar 19 23:44:00 2018, gautam, Update, IOO, IMC loop checkup IMC_RF_noise.pdfIMC_OLTF_20180320.pdf
    Reply  Tue Mar 20 16:53:03 2018, gautam, Update, IOO, IMC loop checkup IMC_RF_noise.pdf
       Reply  Tue Mar 20 21:08:03 2018, gautam, Update, IOO, IMC loop checkup 
          Reply  Tue Mar 20 22:44:45 2018, gautam, Update, IOO, IMC loop checkup 
             Reply  Wed Mar 21 15:52:45 2018, gautam, Update, IOO, MC error point calibration IMC_PDHdisc_20180321.pdfIMC_PDHdisc785_20180321.pdfIMC_oscope.pdf
                Reply  Wed Mar 21 17:31:21 2018, gautam, Update, IOO, MC error point calibration IMC_RF_noise_calib.pdf
                   Reply  Wed Mar 21 21:13:44 2018, gautam, Update, IOO, IMC noise budget IMC_RF_noise_calib.pdf
                      Reply  Tue Mar 27 01:39:44 2018, gautam, Update, IOO, PSL noise eater was off IR_ALS_20180326.pdf
                         Reply  Tue Mar 27 19:32:03 2018, arijit, Update, IOO, PSL noise eater was off MCREFL_TF.pdfMCREFL_SPECTRUM.pdf
                            Reply  Tue Mar 27 23:37:35 2018, gautam, Update, IOO, MC REFL PD removed IMG_6955.JPG
                               Reply  Wed Mar 28 21:31:39 2018, gautam, Update, IOO, MC REFL PD removed 
                            Reply  Wed Mar 28 21:47:37 2018, arijit, Update, IOO, MCREFL_PD Optical response measurement LISO_fit_with_info.pdfLISO_fit.zip
                               Reply  Thu Mar 29 17:57:36 2018, arijit, Update, IOO, MCREFL_PD Optical response measurement NOISE_EATER_On_OFF.pdf
                                  Reply  Fri Mar 30 06:14:31 2018, rana, Update, IOO, MCREFL_PD Optical response measurement 
                                     Reply  Fri Mar 30 22:37:36 2018, Kevin, Update, IOO, MCREFL_PD Optical response measurement REFLPD_DemodBoard.pdf
                      Reply  Thu Apr 5 04:36:56 2018, Kevin, Update, IOO, Coil driver noise MC3.pdfMC2.pdfCoilDriver.pdf
                         Reply  Thu Apr 5 12:13:18 2018, Koji, Update, IOO, Coil driver noise 
                            Reply  Fri Apr 6 21:39:09 2018, gautam, Update, IOO, MC2 suspension health checkup MC2_Freeswinging.pdf
                               Reply  Mon Apr 9 18:46:03 2018, gautam, Update, IOO, Further debugging MC_Freeswinging.pdfIMC_NB_20180409.pdf
                                  Reply  Tue Apr 10 14:28:44 2018, gautam, Update, IOO, Further debugging 
                                     Reply  Wed Apr 11 01:34:31 2018, gautam, Update, IOO, Activities today 
                                        Reply  Thu Apr 12 18:12:49 2018, gautam, Update, ALS, NPRO channels hijacked IR_ALS_20180412.pdfBeatMouthDrift.pngETMX_20180416.jpg
                                           Reply  Fri Apr 13 11:02:41 2018, gautam, Update, ALS, EX fiber polarization drift EX_pol_drift.png
                                              Reply  Fri Apr 13 17:56:26 2018, gautam, Update, ALS, Fibers switched out 
                                                 Reply  Sat Apr 14 14:42:09 2018, gautam, Update, ALS, Fibers switched out PSLdrift.png
                                                    Reply  Tue Apr 17 14:08:29 2018, gautam, Update, ALS, Fibers switched out PSL_fluctuations.png
                                                       Reply  Fri Apr 20 00:26:34 2018, gautam, Update, ALS, Fibers switched out 
                                                          Reply  Sat Apr 21 20:25:12 2018, gautam, Update, ALS, PSL fiber pickoff status PSL-beatMouthPickoff.png
                                  Reply  Thu Apr 19 00:03:51 2018, gautam, Update, IOO, More IMC NBing IMC_NB_20180409.pdfIMC_coils_20180418.pdf
                                     Reply  Thu Apr 19 17:15:35 2018, gautam, Update, IOO, More IMC NBing IMC_NB_20180419.pdfIMC_coilDriverNoises_20180419.pdf
                                        Reply  Sun May 20 23:43:50 2018, gautam, Update, IOO, Coil driver noise re-measurement MC1_coilDriver.pdfMC2_coilDriver.pdfMC3_coilDriver.pdfMC_coilDriverNoises.tgzActuationChainNoiseMeas.pdf
                                           Reply  Tue May 22 17:26:25 2018, gautam, Update, IOO, MC1 Coil Driver pulled out 
                                              Reply  Tue May 22 23:28:01 2018, gautam, Update, IOO, MC1 Coil Driver pulled out 
                                                 Reply  Wed May 23 17:58:48 2018, gautam, Update, IOO, MC1 Coil Driver pulled out MC1_monitorTF.pngMC1_ULnoise.pdf
                                                    Reply  Wed May 30 10:17:46 2018, gautam, Update, IOO, MC1 Coil Driver pulled out EM_pickup.pdfcoilDriverNoiseComparison.pdf
                            Reply  Fri Apr 6 22:23:53 2018, Kevin, Update, IOO, Coil driver noise MC2_coil_driver.pdf
Message ID: 13738     Entry time: Fri Apr 6 22:23:53 2018     In reply to: 13730
Author: Kevin 
Type: Update 
Category: IOO 
Subject: Coil driver noise 

 

Quote:

Why is MC2 LR so different from the others???

The previous measurements were made from the coil driver output monitors. To investigate why the MC2 LR coil has less noise than the other coils, I also measured the noise at the output to the coils.

The circuit diagram for the coil driver board is given in D010001 and a picture of the rack is on the 40m wiki here. The coil driver boards are in the upper left quadrant of the rack. The input to the board is the column of LEMOs which are the "Coil Test In" inputs on the schematic. The output monitors are the row of LEMOs to the right of the input LEMOs and are the "FP Coil Volt Mon" outputs on the schematic. The output to the coils "Coil Out" in the schematic are carried through a DB15 connector.

The attachment shows the voltage noise for the MC2 LR coil as well as the UL coil which is similar to all of the other coils measured in the previous measurement. While the LR coil is less noisy than the UL coil as measured at the output monitor, they have the same noise spectrum as measured at the output to the coils themselves. So there must be something wrong with the buffer circuit for the MC2 LR voltage monitor, but the output to the coils themselves is the same as for the other coils.

Attachment 1: MC2_coil_driver.pdf  39 kB  Uploaded Fri Apr 6 23:34:00 2018  | Hide | Hide all
MC2_coil_driver.pdf
ELOG V3.1.3-