Mon Mar 19 23:44:00 2018, gautam, Update, IOO, IMC loop checkup 
|
Tue Mar 20 16:53:03 2018, gautam, Update, IOO, IMC loop checkup
|
Tue Mar 20 21:08:03 2018, gautam, Update, IOO, IMC loop checkup
|
Tue Mar 20 22:44:45 2018, gautam, Update, IOO, IMC loop checkup
|
Wed Mar 21 15:52:45 2018, gautam, Update, IOO, MC error point calibration  
|
Wed Mar 21 17:31:21 2018, gautam, Update, IOO, MC error point calibration
|
Wed Mar 21 21:13:44 2018, gautam, Update, IOO, IMC noise budget
|
Tue Mar 27 01:39:44 2018, gautam, Update, IOO, PSL noise eater was off
|
Tue Mar 27 19:32:03 2018, arijit, Update, IOO, PSL noise eater was off 
|
Tue Mar 27 23:37:35 2018, gautam, Update, IOO, MC REFL PD removed
|
Wed Mar 28 21:31:39 2018, gautam, Update, IOO, MC REFL PD removed
|
Wed Mar 28 21:47:37 2018, arijit, Update, IOO, MCREFL_PD Optical response measurement 
|
Thu Mar 29 17:57:36 2018, arijit, Update, IOO, MCREFL_PD Optical response measurement
|
Fri Mar 30 06:14:31 2018, rana, Update, IOO, MCREFL_PD Optical response measurement
|
Fri Mar 30 22:37:36 2018, Kevin, Update, IOO, MCREFL_PD Optical response measurement
|
Thu Apr 5 04:36:56 2018, Kevin, Update, IOO, Coil driver noise  
|
Thu Apr 5 12:13:18 2018, Koji, Update, IOO, Coil driver noise
|
Fri Apr 6 21:39:09 2018, gautam, Update, IOO, MC2 suspension health checkup
|
Mon Apr 9 18:46:03 2018, gautam, Update, IOO, Further debugging 
|
Tue Apr 10 14:28:44 2018, gautam, Update, IOO, Further debugging
|
Wed Apr 11 01:34:31 2018, gautam, Update, IOO, Activities today
|
Thu Apr 12 18:12:49 2018, gautam, Update, ALS, NPRO channels hijacked  
|
Fri Apr 13 11:02:41 2018, gautam, Update, ALS, EX fiber polarization drift
|
Fri Apr 13 17:56:26 2018, gautam, Update, ALS, Fibers switched out
|
Sat Apr 14 14:42:09 2018, gautam, Update, ALS, Fibers switched out
|
Tue Apr 17 14:08:29 2018, gautam, Update, ALS, Fibers switched out
|
Fri Apr 20 00:26:34 2018, gautam, Update, ALS, Fibers switched out
|
Sat Apr 21 20:25:12 2018, gautam, Update, ALS, PSL fiber pickoff status
|
Thu Apr 19 00:03:51 2018, gautam, Update, IOO, More IMC NBing 
|
Thu Apr 19 17:15:35 2018, gautam, Update, IOO, More IMC NBing 
|
Sun May 20 23:43:50 2018, gautam, Update, IOO, Coil driver noise re-measurement    
|
Tue May 22 17:26:25 2018, gautam, Update, IOO, MC1 Coil Driver pulled out
|
Tue May 22 23:28:01 2018, gautam, Update, IOO, MC1 Coil Driver pulled out
|
Wed May 23 17:58:48 2018, gautam, Update, IOO, MC1 Coil Driver pulled out 
|
Wed May 30 10:17:46 2018, gautam, Update, IOO, MC1 Coil Driver pulled out 
|
Fri Apr 6 22:23:53 2018, Kevin, Update, IOO, Coil driver noise
|
|
Message ID: 13724
Entry time: Fri Mar 30 22:37:36 2018
In reply to: 13721
|
Author: |
Kevin |
Type: |
Update |
Category: |
IOO |
Subject: |
MCREFL_PD Optical response measurement |
|
|
[Gautam, Kevin]
We redid the measurement measuring the voltage noise from the REFL PD demod board output monitor with an SR785 with the noise eater on and off. We used a 100x preamp to amplify the signal above the SR785 noise. The SR785 noise floor was measured with the input to the preamp terminated with 50 ohms. The spectra shown have been corrected for the 100x amplification.
This measurement shows no difference with the noise eater on or off.
Quote: |
the noise eater on/off measurements should be done for 0-100 kHz and from the demod board output monitor
|
|
|
|