Thu Dec 7 11:14:37 2017, johannes, HowTo, Computer Scripts / Programs, Lots of red on the FE status screen
|
Thu Dec 7 15:02:37 2017, Koji, HowTo, Computer Scripts / Programs, Lots of red on the FE status screen
|
Thu Dec 7 15:46:31 2017, johannes, HowTo, Computer Scripts / Programs, Lots of red on the FE status screen
|
Thu Dec 7 16:28:06 2017, Koji, Update, IOO, Lots of red on the FE status screen
|
Thu Dec 14 07:07:09 2017, rana, Update, IOO, Lots of red on the FE status screen
|
|
Message ID: 13465
Entry time: Thu Dec 7 15:02:37 2017
In reply to: 13464
Reply to this: 13466
|
Author: |
Koji |
Type: |
HowTo |
Category: |
Computer Scripts / Programs |
Subject: |
Lots of red on the FE status screen |
|
|
Once a realtime machine was rebooted, it did not come back. I suspect that the diskless hosts have a difficulty to boot up. |
|