40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Wed Jan 25 14:30:20 2017, gautam, Update, CDS, slow machine bootfest 
    Reply  Fri Jan 27 17:07:52 2017, Lydia, Update, CDS, slow machine bootfest 
       Reply  Mon Feb 6 15:18:08 2017, gautam, Update, CDS, slow machine bootfest 
          Reply  Thu May 25 12:22:59 2017, gautam, Update, CDS, slow machine bootfest 
             Reply  Thu Jun 1 15:37:01 2017, gautam, Update, CDS, slow machine bootfest 
                Reply  Mon Jun 12 10:34:10 2017, gautam, Update, CDS, slow machine bootfest 
                   Reply  Fri Jun 16 13:53:11 2017, gautam, Update, CDS, slow machine bootfest 
                      Reply  Wed Jul 5 16:09:34 2017, gautam, Update, CDS, slow machine bootfest 
                         Reply  Wed Aug 30 10:54:26 2017, gautam, Update, CDS, slow machine bootfest 
                            Reply  Tue Sep 5 23:02:37 2017, gautam, Update, CDS, slow machine bootfest 
                               Reply  Tue Oct 3 19:39:10 2017, gautam, Update, CDS, slow machine bootfest 
                                  Reply  Thu Oct 5 11:46:15 2017, gautam, Update, CDS, slow machine bootfest 
                                     Reply  Thu Oct 12 14:42:45 2017, gautam, Update, CDS, slow machine bootfest 
                                        Reply  Mon Oct 30 11:15:02 2017, gautam, Update, CDS, slow machine bootfest + vacuum snafu 
                                           Reply  Mon Nov 6 11:15:43 2017, gautam, Update, CDS, slow machine bootfest + IFO re-alignment 
                                              Reply  Tue Jan 9 11:52:29 2018, gautam, Update, CDS, slow machine bootfest 
                                                 Reply  Wed Jan 10 12:24:52 2018, gautam, Update, CDS, slow machine bootfest 
                                                    Reply  Fri Jan 19 11:13:21 2018, gautam, Update, CDS, slow machine bootfest 
                                                       Reply  Wed Apr 4 16:23:39 2018, gautam, Update, CDS, slow machine bootfest 
                                                          Reply  Wed Apr 18 10:44:45 2018, gautam, Update, CDS, slow machine bootfest MCautolocker_MEDM_revamp.png
                                                             Reply  Thu May 3 12:19:13 2018, gautam, Update, CDS, slow machine bootfest 
                                                                Reply  Thu Jun 7 12:20:53 2018, gautam, Update, CDS, slow machine bootfest ITMX_stuck.png
          Reply  Tue Oct 24 16:43:11 2017, Steve, Update, CDS, slow machine bootfest 
Message ID: 13410     Entry time: Mon Nov 6 11:15:43 2017     In reply to: 13408     Reply to this: 13518
Author: gautam 
Type: Update 
Category: CDS 
Subject: slow machine bootfest + IFO re-alignment 

Eurocrate key turning reboots today morning for and c1susaux, c1auxex and c1auxey. Usual precautions were taken to minimize risk of ITMX getting stuck.

The IFO hasn't been aligned in ~1week, so I recovered arm and PRM alignment by locking individual arms and also PRMI on carrier. I will try recovering DRMI locking in the evening.

As far as MC1 glitching is concerned, there hasn't been any major one (i.e. one in which MC1 is kicked by such a large amount that the autolocker can't lock the IMC) for the past 2 months - but the MC WFS offsets are an indication of when smaller glitches have taken place, and there were large DC offsets on the MC WFS servo outputs, which I offloaded to the DC MC suspension sliders using the MC WFS relief script.

I'd like for the save-restore routine that runs when the slow machines reboot to set the watchdog state default to OFF (currently, after a key-turning reboot, the watchdogs are enabled by default), but I'm not really sure how this whole system works. The relevant files seem to be in the directory /cvs/cds/caltech/target/c1susaux. There is a script in there called startup.cmd, which seems to be the initialization script that runs when the slow machine is rebooted. But looking at this file, it is not clear to me where the default values are loaded from? There are a few "saverestore" files in this directory as well:

  • saverestore.sav
  • saverestore.savB
  • saverestore.sav.bu
  • saverestore.req

Are the "default" channel values loaded from one of these?