40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Mon Sep 11 23:31:50 2017, johannes, Update, Cameras, post-vent camera capture comparison 13x
    Reply  Tue Sep 26 22:11:08 2017, johannes, Update, Cameras, post-vent camera capture comparison lens_distance.pdfImage__2017-09-26__18-54-29.jpgIMG_20170926_190157222_HDR.jpgIMG_20170926_185649325.jpg
       Reply  Mon Oct 2 12:44:45 2017, johannes, Update, Cameras, Basler 120gm calibration calib_20170930_152.pdfcalib_20170930_153.pdf
          Reply  Mon Oct 2 23:16:05 2017, gautam, HowTo, Cameras, CCD calibration 
             Reply  Tue Oct 3 01:58:32 2017, johannes, HowTo, Cameras, CCD calibration gige_calibration.pdf
                Reply  Thu Oct 12 01:03:49 2017, johannes, HowTo, Cameras, ETMX GigE side view IMG_20171011_164549698.jpgImage__2017-10-11__16-52-01.pngGigE_lens_position_helper.py.zip
                   Reply  Thu Oct 12 07:56:33 2017, Steve, HowTo, Cameras, ETMX GigE side view at 50 deg of IR scattering Image__2017-10-11__15-29-52_15k400g.pngImage__2017-10-12__15-50-18wipedRefocud2.pngcamCan16cm.jpg
                      Reply  Wed Oct 18 11:37:58 2017, johannes, HowTo, Cameras, ETMX GigE side view at 50 deg 
                Reply  Wed Oct 18 15:26:58 2017, johannes, HowTo, Cameras, Revision: CCD calibration calib_20170930_152.pdfcalib_20170930_153.pdf
Message ID: 13375     Entry time: Thu Oct 12 01:03:49 2017     In reply to: 13354     Reply to this: 13377
Author: johannes 
Type: HowTo 
Category: Cameras 
Subject: ETMX GigE side view 

I calculated a better lens solution for the ETMX side view with the simple python script that's attached. The camera is still not as close to the viewport as we would like, and now the front lens is almost all the up to the end of the tube. With a little more playing around there maybe a better way, especially if we expand the repertoire of focal lengths. Using Steve's wonderful camera fixture I put the beam spot in focus. I turned the camera sideways for better use of the field of view, and now the beam spot actually fills the center area of the beam, to the point where we probably don't want more magnification or else we start losing the tails of the Gaussian.

We'll take a serious of images tomorrow, and will have an estimate of the scatter loss by the end of tomorrow.

 

Attachment 1: IMG_20171011_164549698.jpg  1.824 MB  | Hide | Hide all | Show all
IMG_20171011_164549698.jpg
Attachment 2: Image__2017-10-11__16-52-01.png  107 kB  | Show | Hide all | Show all
Attachment 3: GigE_lens_position_helper.py.zip  762 Bytes  Uploaded Thu May 30 16:27:30 2019
ELOG V3.1.3-