40m
QIL
Cryo_Lab
CTN
SUS_Lab
TCS_Lab
OMC_Lab
CRIME_Lab
FEA
ENG_Labs
OptContFac
Mariner
WBEEShop
|
40m Log |
Not logged in |
 |
|
Wed Sep 6 01:09:11 2017, johannes, Update, Computer Scripts / Programs, New set of loss measurements 
|
Mon Sep 11 12:56:40 2017, johannes, Update, Computer Scripts / Programs, lossmap attempts
|
Mon Sep 11 16:46:09 2017, Steve, Update, PEM, earthquakes
|
Tue Sep 19 14:00:41 2017, Steve, Update, PEM, earthquakes
|
Fri Oct 27 09:34:20 2017, Steve, Update, PEM, earthquakes
|
Fri Nov 10 13:46:26 2017, Steve, Update, PEM, M3.1 local earthquake
|
Mon Apr 9 08:39:39 2018, Steve, Update, PEM, M5.3 eq Souther CA  
|
Thu Jan 25 08:27:25 2018, Steve, Update, PEM, earthquakes  
|
Mon Sep 25 17:56:33 2017, johannes, Update, Computer Scripts / Programs, transmitted power during lossmap
|
Thu Oct 11 13:40:51 2018, yuki, Update, Computer Scripts / Programs, loss measurements
|
Fri Oct 12 12:29:34 2018, yuki, Update, Computer Scripts / Programs, loss measurements
|
Fri Oct 12 20:20:29 2018, yuki, Update, Computer Scripts / Programs, loss measurements
|
Sat Oct 13 20:11:10 2018, yuki, Update, Computer Scripts / Programs, loss measurements
|
Mon Oct 15 10:32:13 2018, yuki, Update, Computer Scripts / Programs, loss measurements 
|
Tue Oct 16 00:44:29 2018, yuki, Update, Computer Scripts / Programs, loss measurements
|
Fri Nov 2 19:25:16 2018, gautam, Update, Computer Scripts / Programs, loss measurements
|
Mon Oct 15 12:52:54 2018, yuki, Update, Computer Scripts / Programs, additional comments
|
Fri Nov 2 16:42:31 2018, aaron, Update, Computer Scripts / Programs, arm loss measuremenents
|
Mon Nov 5 13:52:18 2018, aaron, Update, Computer Scripts / Programs, arm loss measuremenents
|
Tue Nov 6 10:19:26 2018, aaron, Update, Computer Scripts / Programs, arm loss measuremenents
|
Tue Nov 6 15:23:48 2018, gautam, Update, IOO, IMC problematic
|
Tue Nov 6 19:02:35 2018, aaron, Update, IOO, IMC problematic
|
Sat Nov 10 17:40:00 2018, aaron, Update, IOO, IMC problematic
|
Mon Nov 12 13:53:20 2018, rana, Update, IOO, loss measurement: oscope vs CDS DAQ
|
Thu Nov 15 10:21:07 2018, aaron, Update, IOO, IMC problematic 
|
Fri Nov 16 10:53:07 2018, aaron, Update, IOO, IMC problematic
|
Sat Nov 17 18:59:01 2018, aaron, Update, IOO, IMC problematic
|
Wed Nov 7 05:16:16 2018, yuki, Update, Computer Scripts / Programs, arm loss measuremenents
|
|
Message ID: 13309
Entry time: Mon Sep 11 16:46:09 2017
In reply to: 13307
Reply to this: 13322
|
Author: |
Steve |
Type: |
Update |
Category: |
PEM |
Subject: |
earthquakes |
|
|
Quote: |
I was trying to get a lossmap measurement over the weekend but had some trouble first with the IMC and then with the PMC.
For the IMC: It was a bit too misaligned to catch and maintain lock, but I had a hard time improving the alignment by hand. Fortunately, turning on the WFS quickly once it was locked restored the transmission to nominal levels and made it maintain the lock for longer, but only for several minutes, not enough for a lossmap scan (can take up to an hour). Using the WFS information I manually realigned the IMC, which made locking easier but wouldn't help with staying locked.
For the PMC: The PZT feedback signal had railed and the PMC had been unlocked for 8+ hours. The PMC medm screen controls were generally responsive (I could see the modes on the CCDs changing) but I just couldn't get it locked. c1psl was responding to ping but refusing telnet so I keyed the crate, followed by a burt restore and finally it worked.
After the PMC came back the IMC has already maintained lock for more than an hour, so I'm now running the first lossmap measurements.
|
Southern Mexio is still shaking..... so as we |
|
|