Thu Aug 24 00:39:47 2017, gautam, Update, LSC, DRMI locking attempt
|
Fri Aug 25 01:20:52 2017, gautam, Update, LSC, DRMI locking attempt
|
Wed Aug 30 19:49:33 2017, gautam, Update, LSC, REFL55 demod board debugging
|
Thu Aug 31 00:52:52 2017, gautam, Update, LSC, REFL55 whitening board debugging 
|
Thu Aug 31 03:31:15 2017, gautam, Update, LSC, DRMI re-locked! 
|
Mon Sep 4 16:30:06 2017, gautam, Update, LSC, Oplev loop tweaking
|
Mon Sep 4 18:18:29 2017, rana, Update, LSC, dewhite switching: FOTON settings
|
Tue Sep 5 02:07:49 2017, gautam, Update, LSC, Low Noise DRMI attempt 
|
Wed Sep 6 23:06:30 2017, gautam, Update, LSC, Coil de-whitening switching investigation 
|
Fri Sep 15 16:00:33 2017, gautam, Update, LSC, Sensing measurement
|
Fri Sep 15 17:08:58 2017, gautam, Update, LSC, Coil de-whitening switching investigation
|
Sat Sep 16 10:56:19 2017, rana, Update, LSC, Coil de-whitening switching investigation
|
Fri Sep 22 18:12:27 2017, gautam, Update, LSC, DAC noise measurement (again)
|
Wed Sep 27 22:25:21 2017, gautam, Update, LSC, DAC noise measurement (again)
|
Thu Sep 28 06:35:44 2017, Chris, Update, LSC, DAC noise measurement (again)
|
Thu Sep 28 23:50:04 2017, gautam, Update, LSC, DAC noise measurement (again)
|
Fri Sep 29 18:36:25 2017, gautam, Update, LSC, DAC noise measurement (again)
|
Tue Oct 3 01:32:39 2017, gautam, Update, LSC, Laser intensity noise coupling to MICH (simulated) 
|
|
Message ID: 13300
Entry time: Wed Sep 6 23:06:30 2017
In reply to: 13291
Reply to this: 13313
13314
|
Author: |
gautam |
Type: |
Update |
Category: |
LSC |
Subject: |
Coil de-whitening switching investigation |
|
|
Summary:
Rana suggested checking if the coil de-whitening switching is actually happening in the analog path. I repeated the test detailed here. Attachments #1 and #2 suggest that all the coils for the BS and ITMs are indeed switching .
Details:
- The motivation behind this test was the following - the analog path switching is done by applying some logic voltage to a switch, but if this voltage is common among many switches, the hypothesis was that perhaps individual switches were not getting the required voltage to engage the switching.
- This time FM9 (simulated de-whitening) and FM10 (inverse de-whitening) in the coil output filter modules turned off, so as to maintain a flat TF in the digital domain, but engage the de-whitened analog path (turning off FM9 is supposed to do this).
- There is poor coherence in the measurement above 40Hz so the data there should be neglected. It is hard to get a good measurement at higher frequencies because of the pendulum TF + heavy low pass filtering from the analog de-whitening path.
- But between 10-40Hz, we already see the analog de-whitening TF in the measurement.
- For comparison, I have plotted the measured pendulum TFs for one of the coils from an earlier test (all the coils were roughly at the same level).
So it would seem that there is some other noise which has a 1/f^2 shape and is at the same level we expected the DAC noise to be at. Rana suggested checking coherence with MC transmission to see if this could be laser intensity noise.
I also want to re-do the actuator calibrations for the vertex optics again before re-posting the revised noise budget. |
|
|