Mon Aug 14 19:41:46 2017, Jamie, Update, CDS, front-end/DAQ network down for kernel upgrade, and timing errors
|
Wed Aug 16 17:05:53 2017, Jamie, Update, CDS, front-end/DAQ network down for kernel upgrade, and timing errors
|
Wed Aug 16 17:14:02 2017, Koji, Update, CDS, front-end/DAQ network down for kernel upgrade, and timing errors
|
Wed Aug 16 18:01:28 2017, Jamie, Update, CDS, front-end/DAQ network down for kernel upgrade, and timing errors
|
Wed Aug 16 18:06:01 2017, Koji, Update, CDS, front-end/DAQ network down for kernel upgrade, and timing errors
|
Wed Aug 16 18:50:58 2017, Jamie, Update, CDS, front-end/DAQ network down for kernel upgrade, and timing errors
|
Mon Aug 28 16:20:00 2017, gautam, Update, CDS, 40m files backup situation
|
Mon Aug 28 17:13:57 2017, ericq, Update, CDS, 40m files backup situation
|
Fri Sep 15 15:54:28 2017, gautam, Update, CDS, FB wiper script
|
Mon Sep 18 17:17:49 2017, gautam, Update, CDS, FB wiper script
|
Mon Sep 18 17:30:54 2017, Chris, Update, CDS, FB wiper script
|
Mon Sep 18 17:51:26 2017, gautam, Update, CDS, FB wiper script
|
Mon Sep 18 18:40:34 2017, gautam, Update, CDS, FB wiper script
|
Tue Sep 26 15:55:20 2017, gautam, Update, CDS, 40m files backup situation
|
Thu Sep 28 10:33:46 2017, gautam, Update, CDS, 40m files backup situation
|
Thu Sep 28 11:13:32 2017, jamie, Update, CDS, 40m files backup situation
|
Thu Sep 28 23:47:38 2017, gautam, Update, CDS, 40m files backup situation
|
Fri Sep 29 11:07:16 2017, gautam, Update, CDS, 40m files backup situation
|
Thu Oct 5 13:58:26 2017, gautam, Update, CDS, 40m files backup situation
|
Fri Oct 6 12:46:17 2017, gautam, Update, CDS, 40m files backup situation
|
Sat Oct 28 00:36:26 2017, gautam, Update, CDS, 40m files backup situation - ddrescue 
|
|
Message ID: 13262
Entry time: Mon Aug 28 16:20:00 2017
In reply to: 13219
Reply to this: 13263
13312
13332
|
Author: |
gautam |
Type: |
Update |
Category: |
CDS |
Subject: |
40m files backup situation |
|
|
This elog is meant to summarize the current backup situation of critical 40m files.
What are the critical filesystems? I've also indicated the size of these disks and the volume currently used, and the current backup situation.
Name
|
Disk Usage
|
Description / remarks
|
Current backup status
|
FB1 root filesystem |
1.7TB / 2TB |
- FB1 is the machine that hosts the diskless root for the front end machines
- Additionally, it runs the daqd processes which write data from realtime models into frame files
|
Not backed up |
/frames |
up to 24TB |
- This is where the frame files are written to
- Need to setup a wiper script that periodically clears older data so that the disk doesn't overflow.
|
Not backed up
LDAS pulls files from nodus daily via rsync, so there's no cron job for us to manage. We just allow incoming rsync.
|
Shared user area |
1.6TB / 2TB |
- /home/cds on chiara
- This is exported over NFS to 40m workstations, FB1 etc.
- Contains user directories, scripts, realtime models etc.
|
Local backup on /media/40mBackup on chiara via daily cronjob
Remote backup to ldas-cit.ligo.caltech.edu::40m/cvs via daily cronjob on nodus
|
Chiara root filesystem |
11GB / 440GB |
- This is the root filesystem for chiara
- Contains nameserver stuff for the martian network, responsible for rsyncing /home/cds
|
Not backed up |
Megatron root filesystem |
39GB / 130GB |
- Boot disk for megatron, which is our scripts machine
- Runs MC autolocker, FSS loops etc.
- Also is the nds server for facilitating data access from outside the martian network
|
Not backed up |
Nodus root filesystem |
77GB / 355GB |
- This is the boot disk for our gateway machine
- Hosts Elog, svn, wikis
- Supposed to be responsible for sending email alerts for NFS disk usage and vacuum system N2 pressure
|
Not backed up |
JETSTOR RAID Array |
12TB / 13TB |
- Old /frames
- Archived frames from DRFPMI locks
- Long term trends
|
Currently mounted on Megatron, not backed up.
|
Then there is Optimus, but I don't think there is anything critical on it.
So, based on my understanding, we need to back up a whole bunch of stuff, particularly the boot disks and root filesystems for Chiara, Megatron and Nodus. We should also test that the backups we make are useful (i.e. we can recover current operating state in the event of a disk failure).
Please edit this elog if I have made a mistake. I also don't have any idea about whether there is any sort of backup for the slow computing system code. |