Message ID: 13257     Entry time: Sun Aug 27 11:57:31 2017     In reply to: 13254     Reply to this: 13266
Author: rana 
Type: Update 
Category: ALS 
Subject: Fiber ALS noise measurement 

It seems like the main contribution to the RMS comes from the high frequency bump. When using the ALS loop to lock the arm to the beat, only the stuff below ~100 Hz will matter. Interesting to see what that noise budget will show. Perhaps the discrepancy between inloop and out of loop will go down.