40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Sat Aug 5 11:04:07 2017, gautam, Update, SUS, MC1 glitches return MC1_glitch_Aug42017.pngMC1_glitch_zoomed.png
    Reply  Wed Aug 9 15:15:47 2017, gautam, Update, SUS, MC1 glitches return MC1_glitch.png
       Reply  Thu Aug 10 21:01:43 2017, gautam, Update, SUS, MC1 glitches debugging MC_QUAD_10AUG2017.jpgMCR_10AUG2017.jpg
          Reply  Fri Aug 11 12:32:46 2017, gautam, Update, SUS, MC1 glitches debugging MC1_freeswinging.pdfMC1_inmatrix.pngMC1_sensors.png
             Reply  Fri Aug 11 17:36:47 2017, gautam, Update, SUS, MC1 <--> MC3 MC1_glitch_watchdog_shutdown.png
                Reply  Sat Aug 12 14:09:36 2017, gautam, Update, SUS, Glitches stay on MC1 MC1_glitch.pngMC_12hr_trend.pngMC1_glitches_intermittent.png
                   Reply  Sat Aug 12 22:35:22 2017, rana, Update, SUS, Glitches stay on MC1 
                      Reply  Sun Aug 13 01:35:09 2017, Koji, Update, SUS, Glitches stay on MC1 
                         Reply  Mon Aug 14 20:01:38 2017, gautam, Update, SUS, Glitches stay on MC1 
                Reply  Wed Aug 16 19:50:17 2017, gautam, Update, SUS, MC1 <--> MC3 switched back 
                   Reply  Thu Aug 17 11:17:49 2017, gautam, Update, SUS, MC1 <--> MC3 switched back MC1_misaligned.pngMC1_glitch.png
                      Reply  Thu Aug 17 17:33:01 2017, gautam, Update, SUS, MC1 <--> MC3 switched back 
Message ID: 13226     Entry time: Thu Aug 17 17:33:01 2017     In reply to: 13225
Author: gautam 
Type: Update 
Category: SUS 
Subject: MC1 <--> MC3 switched back 

that's why the Autolocker clears the outputs; we don't want to be holding the offsets from the last ms of lock when it was all messed up; instead it would be best to have a slow (~mHz) relief script that takes the WFS controls and puts them onto the MC SUS sliders. This would then re-align the MC to the input beam rather than the input to the MC. Which is not the best idea.

Quote:

Seems like this modification didn't really work.

 

ELOG V3.1.3-