Entry  Mon Aug 14 19:41:46 2017, Jamie, Update, CDS, front-end/DAQ network down for kernel upgrade, and timing errors 
    Reply  Wed Aug 16 17:05:53 2017, Jamie, Update, CDS, front-end/DAQ network down for kernel upgrade, and timing errors 2017-08-16-163725_1366x495_scrot.png
       Reply  Wed Aug 16 17:14:02 2017, Koji, Update, CDS, front-end/DAQ network down for kernel upgrade, and timing errors 
          Reply  Wed Aug 16 18:01:28 2017, Jamie, Update, CDS, front-end/DAQ network down for kernel upgrade, and timing errors 
             Reply  Wed Aug 16 18:06:01 2017, Koji, Update, CDS, front-end/DAQ network down for kernel upgrade, and timing errors 
       Reply  Wed Aug 16 18:50:58 2017, Jamie, Update, CDS, front-end/DAQ network down for kernel upgrade, and timing errors 2017-08-16-184910_1394x488_scrot.png
          Reply  Mon Aug 28 16:20:00 2017, gautam, Update, CDS, 40m files backup situation 
             Reply  Mon Aug 28 17:13:57 2017, ericq, Update, CDS, 40m files backup situation 
             Reply  Fri Sep 15 15:54:28 2017, gautam, Update, CDS, FB wiper script 
                Reply  Mon Sep 18 17:17:49 2017, gautam, Update, CDS, FB wiper script 
                   Reply  Mon Sep 18 17:30:54 2017, Chris, Update, CDS, FB wiper script wiper.pl
                      Reply  Mon Sep 18 17:51:26 2017, gautam, Update, CDS, FB wiper script perlDiff.png
                         Reply  Mon Sep 18 18:40:34 2017, gautam, Update, CDS, FB wiper script 
             Reply  Tue Sep 26 15:55:20 2017, gautam, Update, CDS, 40m files backup situation 
                Reply  Thu Sep 28 10:33:46 2017, gautam, Update, CDS, 40m files backup situation 
                   Reply  Thu Sep 28 11:13:32 2017, jamie, Update, CDS, 40m files backup situation 
                      Reply  Thu Sep 28 23:47:38 2017, gautam, Update, CDS, 40m files backup situation 
                         Reply  Fri Sep 29 11:07:16 2017, gautam, Update, CDS, 40m files backup situation 
                            Reply  Thu Oct 5 13:58:26 2017, gautam, Update, CDS, 40m files backup situation 
                               Reply  Fri Oct 6 12:46:17 2017, gautam, Update, CDS, 40m files backup situation 
                                  Reply  Sat Oct 28 00:36:26 2017, gautam, Update, CDS, 40m files backup situation - ddrescue 415E2F09-3962-432C-B901-DBCB5CE1F6B6.jpegBFF8F8B5-1836-4188-BDF1-DDC0F5B45B41.jpeg
Message ID: 13218     Entry time: Wed Aug 16 18:06:01 2017     In reply to: 13217
Author: Koji 
Type: Update 
Category: CDS 
Subject: front-end/DAQ network down for kernel upgrade, and timing errors 

We also need to copy chiara's root. What is the best way to get the full image of the root FS?
We may need to restore these root images to a different disk with a different capacity.

Is the dump command good for this?