40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Message ID: 13194     Entry time: Fri Aug 11 12:27:25 2017
Author: Kira 
Type: Update 
Category: PEM 
Subject: temperature sensor 

Used AD592CNZ and AD586 (5V output) to create a circuit that works and is responsive to temperature changes. At room temp, using ~1K resistor, it showed ~0.3V across it, as expected. The voltage went up when we heated it with a heating gun. Next step will be to add in an OP amp and design some experiments to check to see how accurate it is. Thanks to Gautam for helping me with it!

I have attached the working circuit and a close up of the connections.

Attachment 1: IMG_20170811_121608.jpg  3.108 MB  | Show | Hide all | Show all
Attachment 2: IMG_20170811_121619.jpg  3.430 MB  | Hide | Hide all | Show all
IMG_20170811_121619.jpg
ELOG V3.1.3-