40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Wed Jul 19 08:37:21 2017, Jamie, Update, CDS, Update on front-end/DAQ rebuild  
    Reply  Wed Jul 19 14:26:50 2017, Jamie, Update, CDS, Update on front-end/DAQ rebuild  
    Reply  Fri Jul 21 18:03:17 2017, Jamie, Update, CDS, Update on front-end/DAQ rebuild  
       Reply  Sun Jul 23 22:16:55 2017, Jamie, gautam, Update, CDS, front-end now running with new OS, RCG 2017-07-23-210810_1394x488_scrot.png2017-07-23-211812_387x488_scrot.png
          Reply  Mon Jul 24 10:45:23 2017, gautam, Update, CDS, c1iscex models died c1iscexFailure.png
             Reply  Mon Jul 24 10:59:08 2017, Jamie, Update, CDS, c1iscex models died 
          Reply  Mon Jul 24 19:28:55 2017, Jamie, Update, CDS, front end MX stream network working, glitches in c1ioo fixed 48.png
             Reply  Mon Jul 24 19:57:54 2017, gautam, Update, CDS, IMC locked, Autolocker re-enabled 
             Reply  Wed Jul 26 19:13:07 2017, Jamie, Update, CDS, daqd showing same instability as before 
                Reply  Fri Jul 28 20:22:41 2017, Jamie, Update, CDS, possible stable daqd configuration with separate DC and FW 
                   Reply  Mon Jul 31 15:13:24 2017, gautam, Update, CDS, FB ---> FB1 
                   Reply  Mon Jul 31 18:44:40 2017, Jamie, Update, CDS, CDS system essentially fully recovered 02.png
                      Reply  Thu Aug 3 19:46:27 2017, Jamie, Update, CDS, new daqd restart procedure 
                      Reply  Fri Aug 4 09:07:28 2017, rana, Update, CDS, CDS system essentially NOT fully recovered 
                         Reply  Thu Aug 10 14:25:52 2017, gautam, Update, CDS, Slow EPICS channels -> Frames re-enabled 
                            Reply  Fri Aug 11 00:10:03 2017, gautam, Update, CDS, Slow EPICS channels -> Frames re-enabled 
                               Reply  Fri Aug 11 11:14:24 2017, gautam, Update, CDS, Slow EPICS channels -> Frames re-enabled 
                               Reply  Fri Aug 11 18:53:35 2017, gautam, Update, CDS, Slow EPICS channels -> Frames re-enabled 
                      Reply  Fri Aug 11 19:34:49 2017, Jamie, Update, CDS, CDS final bits status update 
Message ID: 13192     Entry time: Fri Aug 11 11:14:24 2017     In reply to: 13189
Author: gautam 
Type: Update 
Category: CDS 
Subject: Slow EPICS channels -> Frames re-enabled 

I commented out the line pertaining to C0EDCU again, now full frames are being written again.

But we no longer have access to the slow EPICS records.

I am not sure what the failure mode is here - In the master file, there is a line that says the EDCU list "*MUST* COME *AFTER* ALL OTHER FAST INI DEFINITIONS" which it does. But there are a bunch of lines that are testpoint lists after this EDCU line. I wonder if that is the problem?

Quote:

Seems like something has failed after I did this - full frames are no longer on Aug 10 being written since ~2.30pm PDT. I found out when I tried to download some of the free-swinging MC1 data.

 