Entry  Wed Jul 19 08:37:21 2017, Jamie, Update, CDS, Update on front-end/DAQ rebuild  
    Reply  Wed Jul 19 14:26:50 2017, Jamie, Update, CDS, Update on front-end/DAQ rebuild  
    Reply  Fri Jul 21 18:03:17 2017, Jamie, Update, CDS, Update on front-end/DAQ rebuild  
       Reply  Sun Jul 23 22:16:55 2017, Jamie, gautam, Update, CDS, front-end now running with new OS, RCG 2017-07-23-210810_1394x488_scrot.png2017-07-23-211812_387x488_scrot.png
          Reply  Mon Jul 24 10:45:23 2017, gautam, Update, CDS, c1iscex models died c1iscexFailure.png
             Reply  Mon Jul 24 10:59:08 2017, Jamie, Update, CDS, c1iscex models died 
          Reply  Mon Jul 24 19:28:55 2017, Jamie, Update, CDS, front end MX stream network working, glitches in c1ioo fixed 48.png
             Reply  Mon Jul 24 19:57:54 2017, gautam, Update, CDS, IMC locked, Autolocker re-enabled 
             Reply  Wed Jul 26 19:13:07 2017, Jamie, Update, CDS, daqd showing same instability as before 
                Reply  Fri Jul 28 20:22:41 2017, Jamie, Update, CDS, possible stable daqd configuration with separate DC and FW 
                   Reply  Mon Jul 31 15:13:24 2017, gautam, Update, CDS, FB ---> FB1 
                   Reply  Mon Jul 31 18:44:40 2017, Jamie, Update, CDS, CDS system essentially fully recovered 02.png
                      Reply  Thu Aug 3 19:46:27 2017, Jamie, Update, CDS, new daqd restart procedure 
                      Reply  Fri Aug 4 09:07:28 2017, rana, Update, CDS, CDS system essentially NOT fully recovered 
                         Reply  Thu Aug 10 14:25:52 2017, gautam, Update, CDS, Slow EPICS channels -> Frames re-enabled 
                            Reply  Fri Aug 11 00:10:03 2017, gautam, Update, CDS, Slow EPICS channels -> Frames re-enabled 
                               Reply  Fri Aug 11 11:14:24 2017, gautam, Update, CDS, Slow EPICS channels -> Frames re-enabled 
                               Reply  Fri Aug 11 18:53:35 2017, gautam, Update, CDS, Slow EPICS channels -> Frames re-enabled 
                      Reply  Fri Aug 11 19:34:49 2017, Jamie, Update, CDS, CDS final bits status update 
Message ID: 13189     Entry time: Fri Aug 11 00:10:03 2017     In reply to: 13185     Reply to this: 13192   13197
Author: gautam 
Type: Update 
Category: CDS 
Subject: Slow EPICS channels -> Frames re-enabled 

Seems like something has failed after I did this - full frames are no longer on Aug 10 being written since ~2.30pm PDT. I found out when I tried to download some of the free-swinging MC1 data.

To clarify, I logged into fb1, and ran sudo systemctl restart daqd_*. The only change I made was to uncomment the line quoted below in the master file.

Looking at the log using systemctl, I see the following (I just tried restarting the daqd processes again):

Aug 11 00:00:31 fb1 daqd_fw[16149]: LDASUnexpected::unexpected: Caught unexpected exception      "This is a bug. Please log an LDAS problem report including this message.
Aug 11 00:00:31 fb1 daqd_fw[16149]: daqd_fw: LDASUnexpected.cc:131: static void LDASTools::Error::LDASUnexpected::unexpected(): Assertion `false' failed.
Aug 11 00:00:32 fb1 systemd[1]: daqd_fw.service: main process exited, code=killed, status=6/ABRT
Aug 11 00:00:32 fb1 systemd[1]: Unit daqd_fw.service entered failed state.
Aug 11 00:00:32 fb1 systemd[1]: daqd_fw.service holdoff time over, scheduling restart.
Aug 11 00:00:32 fb1 systemd[1]: Stopping Advanced LIGO RTS daqd frame writer...
Aug 11 00:00:32 fb1 systemd[1]: Starting Advanced LIGO RTS daqd frame writer...
Aug 11 00:00:32 fb1 systemd[1]: daqd_fw.service start request repeated too quickly, refusing to start.
Aug 11 00:00:32 fb1 systemd[1]: Failed to start Advanced LIGO RTS daqd frame writer.
Aug 11 00:00:32 fb1 systemd[1]: Unit daqd_fw.service entered failed state.

Oddly, I am able to access second trends for the same channels from the past which will be useful for the MC1 debugging). Not sure whats going on.


The live data grabbing using cdsutils still seems to be working though - so I've kicked MC1 again, and am grabbing 2 hours of data live on Pianosa.

Quote:

I went into /opt/rtcds/caltech/c1/target/daqd, opened the master file, and uncommented the line with C0EDCU.ini (this is the file in which all the slow machine channels are defined). So now I am able to access, for example, the c1vac1 channels.

The location of the master file is no longer in /opt/rtcds/caltech/c1/target/fb, but is in the above mentioned directory instead. This is part of the new daqd paradigm in which separate processes are handling the data transfer between FEs and FB, and the actual frame-writing. Jamie will explain this more when he summarizes the CDS revamp.

It looks like trend data is also available for these newly enabled channels, but thus far, I've only checked second trends. I will update with a more exhaustive check later in the evening.

So, the two major pending problems (that I can think of) are:

  1. Inability to unload models cleanly
  2. Inability of dataviewer (and cdsutils) to open testpoints.

Apart from this, dataviewer frequently hangs on Donatella at startup. I used ipcs -a | grep 0x | awk '{printf( "-Q %s ", $1 )}' | xargs ipcrm to remove all the extra messages in the dataviewer queue.


Restarting the daqd processes on fb1 using Jamie's instructions from earlier in this thread works - but the mx_stream processes do not seem to come back automatically on c1lsc, c1sus and c1ioo (reasons unknown). I've made a copy of the mxstreamrestart.sh script with the new mxstream restart commands, called mxstreamrestart_debian.sh, which lives in /opt/rtcds/caltech/c1/scripts/cds. I've also modified the CDS overview MEDM screen such that the "mxstream restart" calls this modified script. For now, this requires you to enter the controls password for each machine. I don't know what is a secure way to do it otherwise, but I recall not having to do this in the past with the old mxstreamrestart.sh script.

 

ELOG V3.1.3-