Thu Aug 3 00:59:33 2017, gautam, Update, CDS, NDS2 server restarted, /frames mounted on megatron
|
Thu Aug 3 10:51:32 2017, rana, Update, CDS, NDS2 server restarted, /frames mounted on megatron
|
Thu Aug 3 11:11:29 2017, gautam, Update, CDS, NDS2 server restarted, /frames mounted on nodus
|
Tue Sep 5 14:41:58 2017, gautam, Update, CDS, NDS2 server restarted on megatron
|
Tue Sep 26 13:40:45 2017, gautam, Update, CDS, NDS2 server restarted on megatron
|
|
Message ID: 13163
Entry time: Thu Aug 3 11:11:29 2017
In reply to: 13162
Reply to this: 13293
|
Author: |
gautam |
Type: |
Update |
Category: |
CDS |
Subject: |
NDS2 server restarted, /frames mounted on nodus |
|
|
I added nodus' eth0 IP (192.168.113.200) to the list of allowed nfs clients in /etc/exportfs on fb1, and then ran sudo mount -a on nodus. Now /frames is mounted.
Quote: |
needs more debugging - this is the machine that allows us to have backed up frames in LDAS. Permissions issues from fb1 ?
|
|