Tue Jan 31 15:08:13 2017, ericq, Metaphysics, CDS, Minute Trend Koan
|
Tue Jan 31 17:28:36 2017, rana, Summary, CDS, Minute Trend Koan
|
Tue Jan 31 20:25:26 2017, ericq, Summary, CDS, Minute Trend Koan
|
Thu Feb 2 18:28:29 2017, rana, Summary, CDS, Minute Trend Koan
|
Fri Feb 3 11:40:34 2017, ericq, Summary, CDS, /cvs/cds/caltech/chans back on svn1.6
|
Sat Feb 4 12:00:59 2017, rana, Summary, CDS, /cvs/cds/caltech/chans back on svn1.6
|
Sat Feb 4 12:20:39 2017, jamie, Summary, CDS, /cvs/cds/caltech/chans back on svn1.6
|
Sat Feb 4 12:29:20 2017, jamie, Summary, CDS, /cvs/cds/caltech/chans back on svn1.6
|
Sat Feb 4 12:50:01 2017, jamie, Summary, CDS, /cvs/cds/caltech/chans back on svn1.6
|
Tue Mar 28 21:06:53 2017, rana, Summary, CDS, /cvs/cds/caltech/chans back on svn1.6
|
Thu Aug 31 00:46:57 2017, rana, Summary, CDS, allegra -> Scientific Linux 7.3
|
|
Message ID: 12791
Entry time: Thu Feb 2 18:28:29 2017
In reply to: 12779
Reply to this: 12796
|
Author: |
rana |
Type: |
Summary |
Category: |
CDS |
Subject: |
Minute Trend Koan |
|
|
and the song remains the same...
the version of SVN on these workstations is ahead of the one on the other workstations so now we can't do 'svn up' on any of the Ubuntu12 machines. One allegra and optimus I get this error:
controls@allegra|GWsummaries> svn up
Updating '.':
svn: E180001: Unable to connect to a repository at URL 'file:///cvs/cds/caltech/svn/trunk/GWsummaries'
svn: E180001: Unable to open an ra_local session to URL
svn: E180001: Unable to open repository 'file:///cvs/cds/caltech/svn/trunk/GWsummaries'
Quote: |
Quote: |
Someone installed "Debian" on allegra. Why? Dataviewer doesn't work on there. Is there some advantage to making this thing have a different OS than the others? Any objections to going back to Ubuntu12?
|
My elog negligence punchcard is getting pretty full... It's pretty much for the same reason as using Debian for optimus; much of the workstation software is getting packaged for Debian, which could offload our need for setting things up in a custom 40m way. Hacking the debian-focused software.ligo.org repos into Ubuntu has caused me headaches in the past. Allegra wasn't being used often, so I figured it was a good test bed for trying things out.
The dataviewer issue was dataviewer's inability to pull the `fb` out of `fb:8088` in the NDSSERVER env variable. I made a quick fix for it in the dataviewer launching script, but there is probably a better way to do it.
|
I'm not sure if its possible to downgrade our chans repo back to the old one, but I highly recommend that no one do 'svn upgrade' in any of our repos until we remove all of the Debian installs in the 40m lab or hire a full-time sysadmin. |