I measured the output noise of eache stage of ISS servo, and calcurated the noise ratio between input and
output of each stage.
Generaly, each noise ratio corresponds to their transfar function. This means servo filter works well, not
adding extra noise.
I attache example of them.
For 2nd stage, the noise ratio is smaller than transfar function with a few factor. This is because the
input noise is coverd by analyser's noise and ratio between output and input looks small.
This means the input noise of 2nd stage was enough small and all stage before 2nd stage work well |