40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Wed Jan 25 15:41:29 2017, Lydia, Update, IMC, 29.5 MHz modulation depth measurement plan 
    Reply  Wed Jan 25 17:30:03 2017, Koji, Update, IMC, 29.5 MHz modulation depth measurement plan 
       Reply  Wed Jan 25 19:39:07 2017, gautam , Update, IMC, 29.5 MHz modulation depth measurement plan 
          Reply  Fri Jan 27 21:25:11 2017, Lydia, Update, IMC, 29.5 MHz modulation depth  
             Reply  Sat Jan 28 01:25:51 2017, gautam, Update, IMC, 29.5 MHz modulation depth  IMC_mod.pdfLockMCNew.png
                Reply  Mon Jan 30 19:07:48 2017, gautam, Update, IMC, RF AM stabilization box pulled out 
                   Reply  Tue Jan 31 01:07:20 2017, Lydia, Update, IMC, RF AM stabilization box pulled out AM_stablilizer_annotation.pdf
                      Reply  Tue Jan 31 13:46:34 2017, rana, Update, IMC, RF AM stabilization box pulled out 
                         Reply  Tue Jan 31 14:17:48 2017, gautam, Update, IMC, RF AM stabilization box pulled out 
                            Reply  Tue Jan 31 22:07:13 2017, gautam, Update, IMC, RF AM stabilization box revamp 
                            Reply  Tue Jan 31 22:28:39 2017, Lydia, Update, IMC, RF AM stabilization box pulled out AM_noise.pdf
                               Reply  Wed Feb 1 11:51:19 2017, Koji, Update, IMC, RF AM stabilization box pulled out 
                                  Reply  Wed Feb 1 16:45:56 2017, Lydia, Update, IMC, RF AM stabilizer box Modification Plan RF_AM_stabilizer_modification.pdf
                                     Reply  Wed Feb 1 20:49:34 2017, rana, Update, IMC, RF AM stabilizer box Modification Plan 
                                        Reply  Wed Feb 1 23:13:30 2017, Lydia, Update, IMC, RF AM stabilizer box Modification Plan 
                                           Reply  Sun Feb 5 21:56:50 2017, Lydia, Update, IMC, 29.5 MHz stabilizer box replacement 
                                              Reply  Tue Feb 7 12:01:10 2017, Lydia, Update, IMC, 29.5 MHz stabilizer box replacement RF_amp.pdf
                                                 Reply  Tue Feb 7 17:00:55 2017, Lydia, Update, IMC, 29.5 MHz stabilizer box replacement 
                                                    Reply  Fri Feb 10 02:14:10 2017, gautam, Update, IMC, 29.5 MHz stabilizer box replacement 
                                                       Reply  Fri Feb 10 11:41:43 2017, Lydia, Update, IMC, 29.5 MHz stabilizer box replacement 
                                                          Reply  Fri Feb 10 13:24:28 2017, rana, Update, IMC, 29.5 MHz stabilizer box replacement 
                                                             Reply  Fri Feb 10 18:21:21 2017, gautam, Update, IMC, IMC Demod board 
                                                                Reply  Fri Feb 10 19:32:15 2017, Koji, Update, IMC, IMC Demod board 
                                                                   Reply  Sun Feb 12 01:16:57 2017, gautam, Update, IMC, IMC length loop - summary of changes DemodBoardOrthogonality.pdfIMC_PDH.pdfTEK00001.PNGIMC_OLTF.pdfFSS_gain_comparison.pdf
                                                                      Reply  Mon Feb 13 11:55:14 2017, rana, Update, IMC, IMC length loop - summary of changes 
                                                                      Reply  Mon Feb 13 13:34:44 2017, gautam, Update, IMC, IMC length loop - bad SMA cable replaced noisy_PMC_REFL.png
                                                                         Reply  Mon Feb 13 19:44:55 2017, Lydia, Update, IMC, Front panel for 29.5 MHz amplifier box rfAmp.pdf
                                                                            Reply  Wed Mar 1 21:15:40 2017, Lydia, Update, IMC, Front panel for 29.5 MHz amplifier box RF_amp_(1).pdf
                                                                               Reply  Wed Mar 1 23:56:09 2017, gautam, Update, IMC, Front panel for 29.5 MHz amplifier box 
                                                                                  Reply  Thu Mar 2 20:32:18 2017, Lydia, Update, IMC, Front panel for 29.5 MHz amplifier box 
                                                                         Reply  Wed Feb 15 23:54:13 2017, gautam, Update, IMC, IMC saga continues... MCstrip.pngIMCweirdness.png
                                                                            Reply  Fri Feb 17 20:10:18 2017, gautam, Update, IMC, WFS servos turned back on 
                                                                               Reply  Sat Feb 18 14:09:06 2017, rana, Update, IMC, WFS servos turned back on 
                                                                                  Reply  Sat Feb 18 21:50:48 2017, gautam, Update, IMC, WFS servos turned back on WFS_error_noise.pdf
                                                                                     Reply  Sun Mar 5 12:41:23 2017, gautam, Update, IMC, WFS servo-steppin WFS_stepping.pngWFS_comparisons.pdfWFSdigitalAA.pdf
Message ID: 12768     Entry time: Sat Jan 28 01:25:51 2017     In reply to: 12767     Reply to this: 12771
Author: gautam 
Type: Update 
Category: IMC 
Subject: 29.5 MHz modulation depth  

Some more details of our investigation:

  1. Here is a spectrum of the signal to the power combiner on the PSL table, measured on the output of the RF AM Stabilization box.

    Perhaps these sidebands were the ones I observed while looking at the input to the WFS demod board.
  2. The signal looked like a clean sinusoid when viewed on an oscilloscope with input impedance set to 50ohms. There were no sharp features or glitches in the time we observed, except when the 29.5 MHz MEDM slider was increased beyond 5, as noted by Lydia.
  3. We couldn't find a schematic for this RF AM Stabilization servo, so we are not sure what RF output power to the EOM we should expect. Schematic has since been found.
  4. I measured the power level at the input side (i.e. from the crystal) and found that it is ~12dBm, which seems reasonable (the front panel of the box housing the 29.5 MHz oscillator is labelled 13dBm). The schematic for the RF AM stabilization box says we should expect +10dBm at the input side, so all this points to a problem in the RF AM stabilization circuit...
  5. There is an attenuator dial on the front panel of the said RF AM stabilization servo that allows one to tune the power to the LO input of the WFS. Right now, it is set to approximately 7dB of attentuation, which corresponds to -12dBm at the WFS demod board input. I did a quick check to see if turning the dial changed the signal level at the LO input of the WFS board. The dial moves in clicks of 1dB, and the RF power at the LO input of the demod board increased/decreased by ~1dBm for each click the dial was rotated (I only explored the region 3dB-11dB of atttentuation). So it should be possible to increase the LO level to the WFS demod boards, is there any reason we shouldn't increase this to -8bBm (~0.25Vpp into 50ohms, which is around the level Koji verified the mixer to be working well at)?
  6. There were a couple of short ribbon cables which were just lying around on top of the cards in the eurocrate, Koji tells me that these were used as tester cables for checking the whitening filters and that they don't serve any purpose now. These have been removed.
  7. Added a button to IMC MEDM screen to allow easy access to the MEDM screen with slider to control the 29.5MHz modulation depth - though as mentioned in Lydia's elog, at the moment, this slider has no effect on the 29.5MHz power level to the EOM...
Attachment 1: IMC_mod.pdf  23 kB  | Hide | Hide all
IMC_mod.pdf
ELOG V3.1.3-