Entry  Fri Jan 27 17:49:41 2017, jamie, Update, CDS, test of new daqd code on fb1 
    Reply  Fri Jan 27 20:52:36 2017, gautam, Update, CDS, test of new daqd code on fb1 DCerrors.png
       Reply  Sat Jan 28 12:05:57 2017, jamie, Update, CDS, test of new daqd code on fb1 
    Reply  Mon Jan 30 18:41:41 2017, jamie, Update, CDS, TEST ABORTED of new daqd code on fb1 
    Reply  Fri Feb 3 11:03:06 2017, jamie, Update, CDS, more testing fb1; DAQ DOWN DURING TEST 
Message ID: 12765     Entry time: Fri Jan 27 20:52:36 2017     In reply to: 12763     Reply to this: 12769  
Author: gautam 
Type: Update 
Category: CDS 
Subject: test of new daqd code on fb1 

I'm not sure if this is related, but since today morning, I've noticed that the data concentrator errors have returned. Looking at daqd.log, there is a 1 second timing mismatch error that is being generated. Usually, manually running ntpdate on the front ends fixes this problem, but it did not work today.

Attachment 1: DCerrors.png  23 kB  Uploaded Sat Jan 28 00:41:31 2017  | Show | Show all