40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Fri Jan 27 17:49:41 2017, jamie, Update, CDS, test of new daqd code on fb1 
    Reply  Fri Jan 27 20:52:36 2017, gautam, Update, CDS, test of new daqd code on fb1 DCerrors.png
       Reply  Sat Jan 28 12:05:57 2017, jamie, Update, CDS, test of new daqd code on fb1 
    Reply  Mon Jan 30 18:41:41 2017, jamie, Update, CDS, TEST ABORTED of new daqd code on fb1 
    Reply  Fri Feb 3 11:03:06 2017, jamie, Update, CDS, more testing fb1; DAQ DOWN DURING TEST 
Message ID: 12763     Entry time: Fri Jan 27 17:49:41 2017     Reply to this: 12765   12770   12794
Author: jamie 
Type: Update 
Category: CDS 
Subject: test of new daqd code on fb1 

Just FYI I'm running a test of updated daqd code on fb1. 

fb1 has it's own fiber to the daq network switch, so nothing had to be modified to do this test. This *should* not affect anything in the rest of the system, but as we all know these are famous last words....  If something is going haywire, and you can't get in touch with me and can't figure what else to do, you can just log on to fb1 and shut it down.  It's not writing any data to any of the network filesystems.

The daqd code under test is from the latest advLigoRTS 3.2.1 tag, which has daqd stability fixes that will hopefully address the problems we were seeing last time I tried this upgrade.  We'll see...

I'm going to let it run over the weekend, and will check in periodically.

ELOG V3.1.3-