40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Mon Jan 16 23:25:07 2017, gautam, Update, SUS, MC1 SUS electronics investigation 20170116_231625.pngIMG_7175.JPGIMG_7174.JPG
    Reply  Tue Jan 17 21:29:52 2017, gautam, Update, SUS, MC1 SUS electronics investigation 
       Reply  Wed Jan 18 11:40:54 2017, gautam, Update, SUS, MC1 SUS electronics investigation MC1glitches.pngMC1coilGlitches.pngMC1CoilGlitchZoomed.png
          Reply  Wed Jan 18 14:23:47 2017, gautam, Update, SUS, MC1 SUS electronics investigation 
             Reply  Wed Jan 18 18:44:53 2017, gautam, Update, SUS, MC1 SUS electronics investigation MCsatBoxSwitch.png
                Reply  Thu Jan 19 08:25:12 2017, Steve, Update, SUS, MC1 SUS electronics investigation MC1_MC3_ITMY_ETMX_sensors.pngsensors_UL.png
                   Reply  Thu Jan 19 12:00:10 2017, gautam, Update, SUS, MC1 SUS electronics investigation SatBoxSwitchGlitch.png
                      Reply  Thu Jan 19 19:56:09 2017, rana, Update, SUS, MC1 SUS electronics investigation 
                         Reply  Fri Jan 20 11:16:30 2017, gautam, Update, SUS, MC1 SUS electronics investigation MCglitchesReturn.png
                            Reply  Mon Jan 23 10:24:01 2017, Steve, Update, SUS, MC1 SUS electronics investigation 3glitchingSUS.png
Message ID: 12741     Entry time: Thu Jan 19 19:56:09 2017     In reply to: 12739     Reply to this: 12742
Author: rana 
Type: Update 
Category: SUS 
Subject: MC1 SUS electronics investigation 

Might be. Or it might be in the satellite box cabling. Hard to tell without a tester. I recommend you squish the cables on there and lock the MC and get back to the usual business. I'll check on sat. box with Ben.

Quote:

 

Is this sufficient evidence to conclude that the Satellite boxes are to blame? It's hard to explain why the glitches come and go in this fashion, and also the apparent difference in the length of time for which the glitches persist. Here, in almost 24 hours, there is one incidence of glitching, but in yesterday's trend plot, the glitching remains present over several hours... The amplitude of the glitches, and their coincidence in all 5 channels, seems consistent with what we have been seeing though...

 

ELOG V3.1.3-