Wed Jan 11 19:20:23 2017, Max Isi, Update, Summary Pages, December outage
|
Thu Jan 12 23:22:34 2017, rana, Update, Summary Pages, December outage
|
Fri Jan 13 14:33:00 2017, MAX (not Rana), Update, Summary Pages, December outage
|
|
Message ID: 12709
Entry time: Thu Jan 12 23:22:34 2017
In reply to: 12703
Reply to this: 12713
|
Author: |
rana |
Type: |
Update |
Category: |
Summary Pages |
Subject: |
December outage |
|
|
Pages still not working: PEM and MEDM blank.
- Committed existing MEDM grabbing scripts to SVN. Ran the cron job on megatron by hand. It grabs PNG files, but somehow its not getting into the summary pages.
- Changed the MEDM grabbing scripts to use '/usr/bin/env'.
- GW summary log files were numbering in the many thousands, so I moved everything over 320 days old into the OLD/ sub-directory using 'find . -type f -mtime +320 -exec mv {} OLD/ \;' (the semi-colon is needed)
- Did apt-get upgrade on Megatron.
- pinged Max
- Stared at GWsumm docs to see if there's a clue about what (if anything) is wrong with the .ini file.
|