Message ID: 12637     Entry time: Wed Nov 23 15:08:56 2016     In reply to: 12635     Reply to this: 12793
Author: rana 
Type: Update 
Category: IMC 
Subject: MCL Feedback 

In the Generic Pentek interface board, which is used to take in the analog 2-pin LEMO cable from the MC Servo board, there is some analog whitening before the signal is sent into the ADC.

There are jumpers in there to set whether it is 0, 1, or 2 stages of 150:15 (z:p) whitening.

ELOG V3.1.3-