40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Tue Nov 27 15:47:17 2007, rob, Configuration, IOO, MC loop MCsmall.jpg
    Reply  Tue Nov 27 16:18:58 2007, rob, Configuration, IOO, MC loop 
Message ID: 126     Entry time: Tue Nov 27 16:18:58 2007     In reply to: 125
Author: rob 
Type: Configuration 
Category: IOO 
Subject: MC loop 
Reduced the common gain to 22dB in the mcup script, so that the WFS would not blow the lock. The above measure of the OLG was done without the mcWFS running, so may be a low estimate as compared to when the alignment is perfect.
ELOG V3.1.3-