Entry  Fri Nov 4 18:31:05 2016, Lydia, Update, CDS, c1auxex channels/pins for Acromag 
    Reply  Sat Nov 5 15:45:44 2016, rana, Update, CDS, c1auxex channels/pins for Acromag 
       Reply  Mon Nov 7 19:49:44 2016, Johannes, Update, CDS, acromag chassis hooked up to PSL acromag_chassis_location.jpgacromag_chassis_top_view.jpg
          Reply  Tue Nov 8 17:51:09 2016, Lydia, Update, CDS, acromag chassis hooked up to PSL 
             Reply  Mon Nov 21 19:54:13 2016, Johannes, Update, CDS, acromag chassis hooked up to PSL acromag_chassis.jpg
                Reply  Wed Nov 30 11:56:56 2016, Lydia, Update, CDS, Wiring for Acromag auxex replacement auxex_acromag.pdf
                   Reply  Wed Nov 30 14:54:01 2016, Johannes, Update, CDS, Slow machine replacement 
                      Reply  Wed Dec 14 19:16:57 2016, Lydia, Update, CDS, Acromag Binary I/O testing 
                         Reply  Tue Jan 31 22:15:02 2017, Johannes, Update, CDS, vme crate backplane adapter boards vme_backplane_conn_sketch.jpg
                            Reply  Tue Feb 7 19:14:59 2017, Johannes, Update, CDS, vme crate backplane adapter board layout vme_backplane.pdf
                               Reply  Wed Feb 15 00:26:44 2017, Johannes, Update, DAQ, panels and pcbs acromag_chassis_panel.pdfvme_backplane_panel.pdfrfAmp.pdf
                                  Reply  Wed Feb 15 09:06:13 2017, ericq, Update, DAQ, panels and pcbs 
                                     Reply  Wed Feb 15 22:21:12 2017, Lydia, Update, DAQ, panels and pcbs 
Message ID: 12599     Entry time: Fri Nov 4 18:31:05 2016     Reply to this: 12600
Author: Lydia 
Type: Update 
Category: CDS 
Subject: c1auxex channels/pins for Acromag 

Here are the channels we are planning to switch over from c1auxex to Acromag, and their current pin numbers on the existing VME boards. 

Analog inputs: 

C1:SUS-ETMX_UL_AIOut    #C0 S0
C1:SUS-ETMX_LL_AIOut    #C0 S1
C1:SUS-ETMX_UR_AIOut    #C0 S2
C1:SUS-ETMX_LR_AIOut    #C0 S3
C1:SUS-ETMX_Side_AIOut    #C0 S4
C1:SUS-ETMX_OL_SEG1    #C0 S5
C1:SUS-ETMX_OL_SEG2    #C0 S6
C1:SUS-ETMX_OL_SEG3    #C0 S7
C1:SUS-ETMX_OL_SEG4    #C0 S8
C1:SUS-ETMX_OL_X    #C0 S9
C1:SUS-ETMX_OL_Y    #C0 S10
C1:SUS-ETMX_OL_S    #C0 S11
C1:SUS-ETMX_ULPD    #C0 S12
C1:SUS-ETMX_LLPD    #C0 S13
C1:SUS-ETMX_URPD    #C0 S14
C1:SUS-ETMX_LRPD    #C0 S15
C1:SUS-ETMX_SPD    #C0 S16
C1:SUS-ETMX_ULV    #C0 S17
C1:SUS-ETMX_LLV    #C0 S18
C1:SUS-ETMX_URV    #C0 S19
C1:SUS-ETMX_LRV    #C0 S20
C1:SUS-ETMX_SideV    #C0 S21
C1:SUS-ETMX_ULPD_MEAN    #C0 S12
C1:SUS-ETMX_LLPD_MEAN    #C0 S13
C1:SUS-ETMX_SDPD_MEAN    #C0 S16

Analog Outputs:

C1:ASC-QPDX_S1WhiteGain    #C0 S0
C1:ASC-QPDX_S2WhiteGain    #C0 S1
C1:ASC-QPDX_S3WhiteGain    #C0 S2
C1:ASC-QPDX_S4WhiteGain    #C0 S3
C1:SUS-ETMX_ULBiasAdj    #C0 S4
C1:SUS-ETMX_LLBiasAdj    #C0 S5
C1:SUS-ETMX_URBiasAdj    #C0 S6
C1:SUS-ETMX_LRBiasAdj    #C0 S7
C1:LSC-EX_GREENLASER_TEMP    #C0 S0 This appears to have the same pin as another channel-- is it not being used? 

Binary Outputs:

C1:SUS-ETMX_UL_ENABLE    #C0 S0
C1:SUS-ETMX_LL_ENABLE    #C0 S1
C1:SUS-ETMX_UR_ENABLE    #C0 S2
C1:SUS-ETMX_LR_ENABLE    #C0 S3
C1:SUS-ETMX_SD_ENABLE    #C0 S4
C1:ASC-QPDX_GainSwitch1    #C0 S7
C1:ASC-QPDX_GainSwitch2    #C0 S8
C1:ASC-QPDX_GainSwitch3    #C0 S9
C1:ASC-QPDX_GainSwitch4    #C0 S10
C1:AUX-GREEN_X_Shutter2    #C0 S15

ELOG V3.1.3-