Message ID: 12597
Entry time: Thu Nov 3 13:36:16 2016
In reply to: 12595
|
Author: |
ericq |
Type: |
Update |
Category: |
CDS |
Subject: |
c1pem revamped |
|
|
It seems that the EX and EY BLRMS banks were missing the BP and LP filters for the 0.03-0.1 and 0.1-0.3 bands. I've copied over the filters from the BS seismometer.
However, if it looks like the integrated C code BLRMS block works out well, we could replace the seismometers' filter module heavy BLRMS blocks and cut down on the PEM model bloat. |