Entry  Tue Oct 25 15:56:11 2016, gautam, Update, General, PRFPMI locked, arms loss improved PRFPMIlock_25Oct2016.pdfITMYwoes.png
    Reply  Tue Oct 25 18:07:28 2016, Koji, Update, General, PRFPMI locked, arms loss improved 
       Reply  Thu Oct 27 12:06:39 2016, gautam, Update, General, PRFPMI locked, arms loss improved PRG.pdf
          Reply  Thu Oct 27 13:48:20 2016, Koji, Update, General, PRFPMI locked, arms loss improved 
             Reply  Thu Oct 27 23:29:47 2016, ericq, Update, General, PRFPMI locked, arms loss improved TRY_REFL_2d.pngAS.pngREFL.pngseis_sub.pdf
                Reply  Fri Oct 28 01:44:48 2016, gautam, Update, General, PRFPMI model vs data studies 6x
                   Reply  Fri Oct 28 19:13:57 2016, rana, Update, General, PR gain 
Message ID: 12580     Entry time: Tue Oct 25 18:07:28 2016     In reply to: 12579     Reply to this: 12583
Author: Koji 
Type: Update 
Category: General 
Subject: PRFPMI locked, arms loss improved 

Great to hear that we have the PRG of ~16 now!

Is this 150ppm an avg loss per mirror, or per arm?

ELOG V3.1.3-