40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Mon Oct 31 15:58:25 2011, steve, Update, SUS, thinking of black glass baffles for 40m 03260901.PDF03260902.PDF
    Reply  Thu Mar 1 09:26:50 2012, steve, Update, SUS, SOS baffle plates are ready 03011201.PDF
       Reply  Wed Oct 12 15:01:22 2016, steve, Update, SUS, SOS ITM baffles plates are ready baffle7x9_1.5.jpgbaffle_holder.jpgbaffle_top_view.jpg
Message ID: 12553     Entry time: Wed Oct 12 15:01:22 2016     In reply to: 6344
Author: steve 
Type: Update 
Category: SUS 
Subject: SOS ITM baffles plates are ready 

The two 40 mm apeture baffles at the ends were replaced by 50 mm one. ITM baffles with 50 mm apeture are baked ready for installation.

Quote:

 Green welding glass 7" x 9"   shade #14 with 40 mm hole and mounting fixtures are ready to reduce scatter light on SOS

PEEK 450CA shims and U-shaped clips  will keep these plates damped.

 

 

Attachment 1: baffle7x9_1.5.jpg  319 kB  | Show | Hide all | Show all
Attachment 2: baffle_holder.jpg  339 kB  | Show | Hide all | Show all
Attachment 3: baffle_top_view.jpg  456 kB  Uploaded Wed Oct 12 16:05:29 2016  | Hide | Hide all | Show all
baffle_top_view.jpg
ELOG V3.1.3-