Thu Aug 25 15:43:29 2016, ericq, Update, SUS, OSEM issues 
|
Thu Aug 25 20:07:35 2016, gautam, Update, SUS, OSEM issues - maybe resolved?
|
Tue Sep 6 18:21:13 2016, rana, Update, SUS, OSEM issues
|
Tue Sep 6 20:52:42 2016, gautam, Update, SUS, OSEM issues
|
Wed Sep 7 17:23:26 2016, gautam, Update, SUS, PRM LR fixed for now 
|
Tue Oct 11 00:43:50 2016, ericq, Update, SUS, PRM LR problematic again  
|
Tue Oct 11 10:15:04 2016, Steve, Update, SUS, PRM LR problematic again
|
Tue Oct 11 13:30:49 2016, gautam, Update, SUS, PRM LR problematic again
|
Wed Oct 12 13:34:28 2016, gautam, Update, SUS, PRM LR problematic again
|
|
Message ID: 12472
Entry time: Tue Sep 6 18:21:13 2016
In reply to: 12441
Reply to this: 12475
|
Author: |
rana |
Type: |
Update |
Category: |
SUS |
Subject: |
OSEM issues |
|
|
I looked at the PRM free swing spectra. The modes look like they're at the right frequencies, so pointing more and more towards a LED or satellite box issue.
|
7/2011 |
9/2016 |
POS |
0.993 |
0.94 |
PIT |
0.612 |
0.60 |
YAW |
0.833 |
0.76 |
SIDE |
0.999 |
0.993 |
Some of the frequencies have changed between the 2011 in-vac measurement and our 2016 in-air measurement, but that seems within usual parameters. |
|
|