40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Fri Feb 19 15:12:38 2016, Koji, Summary, PEM, Guralp Health Check Guralp_Raw_PSD.pdflow_vel_comparison.pdfGuralp_TF.pdf
    Reply  Wed Mar 23 15:23:12 2016, Steve, Summary, PEM, Guralps as connected GUR_A.jpgGUR_B.jpgGUR_Interface_Box.jpg
       Reply  Thu Mar 24 08:20:52 2016, Steve, Update, PEM, Guralp-A calibration sheet 
       Reply  Fri Mar 25 19:17:28 2016, Nikhil, Update, PEM, Guralp Seismometers 16x
          Reply  Fri Mar 25 23:54:04 2016, rana, Update, PEM, Guralp Seismometers 
       Reply  Wed Aug 3 14:52:37 2016, Steve, Summary, PEM, Guralps as connected 
          Reply  Tue Aug 9 13:53:57 2016, babbott, Update, SEI, long Guralp EX cable repaired on the D-sub side 
             Reply  Tue Aug 9 19:35:49 2016, rana, Update, SEI, both Guralp seismometers are functioning and being acquired 1goodday.png
                Reply  Wed Aug 10 10:32:44 2016, Steve, Update, SEI, working Guralps as they are 6x
                   Reply  Fri Aug 12 14:37:34 2016, Steve, Update, SEI, working seismometers as they are eq_2.1m_Geysers_CA.pngeq2.1m_GeysersCA.pngoscillations.png
Message ID: 12385     Entry time: Tue Aug 9 13:53:57 2016     In reply to: 12365     Reply to this: 12389
Author: babbott 
Type: Update 
Category: SEI 
Subject: long Guralp EX cable repaired on the D-sub side 

I checked out the cable that I took from you, and all of the connections looked right.  The only thing I did notice was that some of the soldered wires on the 37-pin connector had gotten hot enough to melt their insulation, and potentially short together.  I cut off that connector, and left it on your desk to check out.  I put on a new connector, and checked the pinout.  If the Guralps still doesn't work, we'll have to check out other possibilities.

ELOG V3.1.3-