40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Message ID: 122     Entry time: Mon Nov 26 10:17:31 2007
Author: steve 
Type: Omnistructure 
Category: SUS 
Subject: etmy sus damping restored 
20 days plot is showing etmy loosing damping 4 times.
I zoomed in with each event. Three of them could of been triggered
by garbage loading just outside. However attachment 2 plot demonstrating that small earthquake or seismic event
did not tripped etmy damping.
The fourth event was preceded by a 4-5 hrs of continous rise of the rms motion at C1:SUS-ETMY_LLPD_VAR
Attachment 1: etmyrms20d.jpg  72 kB  Uploaded Tue Nov 27 10:33:47 2007  | Show | Hide all | Show all
Attachment 2: etmyrmseq.jpg  78 kB  Uploaded Tue Nov 27 11:11:11 2007  | Hide | Hide all | Show all
etmyrmseq.jpg
ELOG V3.1.3-