I've gone through the SOS suspension document (E970037) and some old elogs to get an idea of all the accesories we need for the process of suspending, aside from the tower itself, which Steve has already put together. Gautam and I have laid our eyes upon most of the critical pieces. Some other objects are unknown, and perhaps not strictly neccesary.
Confirmed to exist:
- Guide rod gluing fixture
- 3 axis micrometer + microscope doohicky
- PZT buzzer (for fine standoff positioning)
- Winch fixture (the plate maybe doesn't fit perfectly on the top of the SOS tower, but one bolt will probably work)
- Spare guide rods and ruby standoffs
- Magnet+dumbell gluing fixture (in case we need to glue a new magnet+dumbell pair)
- Magnet to optic gluing fixture (including "pickle pickers"/grippers)
- 0.017" suspension wire
- HeNe laser + QPD + beam height target (confirmed working on scope)
In addition, I am told that we have a long ribbon cable that can run from the X end to the clean room to enable OSEM damping control while we do the pitch alignment.
Things mentioned in the procedure I have not found:
- Something called an "SOS set screw tool" (D961412)
- Not mentioned specifically what this is for
- Edmund scientific pocket measuring microscope + bushing
- Seems to be intended for centering OSEM holding plate on the magnet position. I found no mention of this use in 40m elogs. It can likely be done by eye
- SOS cleaning bracket (D970181)
- This is likely for the old liquinox cleaning procedure. We'll be using first contact.
Some other tasks and their status:
- Check cleanroom table levelling:
- Done via 12" spirit level, looks good
- Glue removal strategy / fixture
- Cut and apply viton tips to earthquake stops
- Either gautam will do this, or we will use the current suspension's stops
|