Wed Jun 8 13:50:39 2016, jamie, Configuration, CDS, Spectracom IRIG-B card installed on fb1
|
Thu Jun 9 13:28:07 2016, jamie, Configuration, CDS, Spectracom IRIG-B card installed on fb1
|
Fri Jun 10 12:09:01 2016, jamie, Configuration, CDS, IRIG-B debugging
|
Fri Jun 10 12:21:54 2016, jamie, Configuration, CDS, GPS receiver not resetting properly
|
Mon Jun 20 11:11:20 2016, Steve, Configuration, CDS, GPS receiver not resetting properly
|
Mon Jun 20 11:19:41 2016, jamie, Configuration, CDS, GPS receiver not resetting properly
|
Mon Jun 20 14:03:04 2016, jamie, Configuration, CDS, EndRun GPS receiver upgraded, fixed
|
Wed Jun 15 10:19:10 2016, Steve, Configuration, CDS, GPS antennas... debugging 6x
|
|
Message ID: 12201
Entry time: Mon Jun 20 11:19:41 2016
In reply to: 12200
Reply to this: 12202
|
Author: |
jamie |
Type: |
Configuration |
Category: |
CDS |
Subject: |
GPS receiver not resetting properly |
|
|
I got the email from them. There was apparently a bug that manifested on February 14 2016. I'll try to software update today.
http://endruntechnologies.com/pdf/FSB160218.pdf
http://endruntechnologies.com/upgradetemplx.htm |