40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Mon Jun 13 20:01:30 2016, varun, Update, CDS, DAFI GUI update C1DAF_OVERVIEW.pngC1DAF_INPUTS.pngC1DAF_LSC.pngMONITOR.png
    Reply  Tue Jun 14 20:10:19 2016, varun, Update, CDS, DAFI GUI update C1DAF_OVERVIEW.pnginput_matrix.pngoutput_matrix.png
       Reply  Wed Jun 15 22:12:55 2016, varun, Update, CDS, DAFI update: stereo output IMG_20160615_145535907.jpgIMG_20160615_145413005_HDR.jpgIMG_20160616_101229499.jpgIMG_20160616_101157096.jpg
          Reply  Wed Jun 22 10:15:45 2016, varun, Update, CDS, DAFI update: stereo output C1DAF_OVERVIEW.pngDAF_link_from_LSC.png
             Reply  Mon Jun 27 15:12:09 2016, varun, Update, CDS, DAFI update: stereo output IMG_20160627_151753247.jpg
Message ID: 12173     Entry time: Mon Jun 13 20:01:30 2016     Reply to this: 12180
Author: varun 
Type: Update 
Category: CDS 
Subject: DAFI GUI update 

Summary: I am implementing digital audio filtering on various interferometer signals in order to listen to the processed audio which will help in characterizing and noise reduction in the interferometer. following is a summary of the gui i have made towards a general purpose DAF module linked to the LSC. 

Details:  attachment 1 shows the top level overview of the daf module.

The "INPUTS" button shown redirects to the medm screen shown in attachment 2, which is a collection of inputs going into the module.

Each of the buttons shown in "C1DAFI_INPUTS.png" is further linked to various i/o boxes like adc1, adc2, lsc signal and exitation. An example is shown in attachment 3. This is the specific I/O box for the LSC signal.

The field labelled "INPUT_MTRX" is linked to a matrix which routes these 4 inputs to various DSP blocks. Similarly, the "OUTPUT_MTRX" tab is useful for choosing which output goes to the speaker. 

Time and computational load monitoring is done in the "GDS_TP" tab which links to the medm screen shown in attachment 4.

Currently the AGC is successfully implemented as one of the DSP block. The details of the AGC implementation were given in a previous elog: https://nodus.ligo.caltech.edu:8081/40m/12159

I need to make a few changes to the code for Frequency Shifting and Whitening before uploading them on the FE. I will put the details soon.

Some more things that I think need to be added: 

1) "Enable" buttons for each of the DSP blocks.

2) Labels for each of the matrix elements.

3) Further headers and other description for each of the tabs 

Attachment 1: C1DAF_OVERVIEW.png  10 kB  | Hide | Hide all | Show all
C1DAF_OVERVIEW.png
Attachment 2: C1DAF_INPUTS.png  2 kB  | Hide | Hide all | Show all
C1DAF_INPUTS.png
Attachment 3: C1DAF_LSC.png  6 kB  | Show | Hide all | Show all
Attachment 4: MONITOR.png  9 kB  | Show | Hide all | Show all
ELOG V3.1.3-