Entry  Thu Apr 28 15:23:11 2016, ericq, Update, LSC, Green PDH demod lowpass 
    Reply  Thu Apr 28 18:53:05 2016, rana, Update, LSC, Green PDH demod lowpass 
       Reply  Fri Apr 29 16:13:36 2016, ericq, Update, LSC, Green PDH demod lowpass IMG_3186.jpgpdh_lpf.pngelp_liso.zip
          Reply  Fri May 6 16:42:12 2016, ericq, Update, LSC, Green PDH demod lowpass pdh_lpf.pngAUX_X_PDH_OLG_May6.png
             Reply  Fri May 6 19:08:52 2016, rana, Update, LSC, Green PDH demod lowpass 
                Reply  Sat May 7 09:40:40 2016, ericq, Update, LSC, Green PDH demod lowpass 
                   Reply  Sun May 8 08:39:21 2016, rana, Update, LSC, Green PDH demod lowpass 
Message ID: 12112     Entry time: Sat May 7 09:40:40 2016     In reply to: 12111     Reply to this: 12113
Author: ericq 
Type: Update 
Category: LSC 
Subject: Green PDH demod lowpass 

As I was looking at filter designs, it seemed difficult to get 40dB of supression at 2F with a bandpass without going to a pretty high order, which would mean a fair number of lossy inductors.

I'll keep working on it. Maybe we don't need 40dB...