Message ID: 12098
Entry time: Thu Apr 28 18:53:05 2016
In reply to: 12097
Reply to this: 12101
|
Author: |
rana |
Type: |
Update |
Category: |
LSC |
Subject: |
Green PDH demod lowpass |
|
|
OK - but give us a circuit diagram and the expected before/after loop plots. Got to make sure we keep the right impedance from PD to mixer. Some of the Thorlabs PDs have a 50 Ohm instead of 0 Ohm source impedance. Maybe you can try it out now since the green arm is ready. |